| Electronic Components Datasheet Search |
|
74LVC1G07GS Datasheet(PDF) 7 Page - Nexperia B.V. All rights reserved |
|
|
|||||||||||||||||||||||||||||
74LVC1G07GS Datasheet(HTML) 7 Page - Nexperia B.V. All rights reserved |
|
7 / 17 page ![]() Nexperia 74LVC1G07 Buffer with open-drain output VEXT VCC VI VO mna616 DUT CL RT RL RL G Test data is given in Table 10. Definitions for test circuit: RL = Load resistance. CL = Load capacitance including jig and probe capacitance. RT = Termination resistance should be equal to the output impedance Zo of the pulse generator. VEXT = External voltage for measuring switching times. Fig. 9. Test circuit for measuring switching times Table 10. Test data Supply voltage Input Load VEXT VCC VI tr, tf CL RL tPZL, tPLZ 1.65 V to 1.95 V VCC ≤ 2.0 ns 30 pF 1 kΩ 2VCC 2.3 V to 2.7 V VCC ≤ 2.0 ns 30 pF 500 Ω 2VCC 2.7 V 2.7 V ≤ 2.5 ns 50 pF 500 Ω 6 V 3.0 V to 3.6 V 2.7 V ≤ 2.5 ns 50 pF 500 Ω 6 V 4.5 V to 5.5 V VCC ≤ 2.5 ns 50 pF 500 Ω 2VCC 74LVC1G07 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2022. All rights reserved Product data sheet Rev. 16 — 3 February 2022 7 / 17 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|