| Electronic Components Datasheet Search |
|
AMS5105 Datasheet(PDF) 4 Page - WOLFSPEED, INC. |
|
|
|||||||||||||||||||||||||||||
AMS5105 Datasheet(HTML) 4 Page - WOLFSPEED, INC. |
|
4 / 8 page ![]() AMS 5105 Pressure sensor with one analog and two switching outputs May 2012 - Rev. 2.0 Page 4/8 www.analogmicro.de Parameter Minimum Typical Maximum Units Long term stability <0.5 %FSO/a Supply voltage (VS ) 4.75 5 5.25 V Current consumption (switching outputs open) 9) 5 mA Resolution A/D converter (analog output) 14 bits Resolution D/A converter 11 bits Resolution analog output signal 0.05 %FSO Resolution of adjustment threshold 10) 14 bit Resolution of adjustment hysteresis 10) 14 bit Load resistance at analog output RL 2k Ω Capacitive load at analog output 50 nF Ratiometricity error (@VS = 4.75…5.25 V) 500 ppm Reaction time (10%...90% rise time) 1 2 ms Load resistance at analog output RL 2k Ω Start-up time (after power on) 5 ms Pressure changes 10 6 Compensated temperature range -25 85 °C Weight 3 g Media compatibility See "Specification notes" 11) 12) Table 3: Specifications SPECIFICATION NOTES 1) The analog voltage output signal is ratiometric to the supply voltage 2) See Table 1 3) The Full Span Output (FSO) is the algebraic difference between the output signal at the specified minimum pressure and the output signal at the specified maximum pressure (see "Pressure ranges"). 4) The two switching outputs (Switch 1 and Switch 2) are software configurable (with the AMS 5105 starter kit). The output modes can be set as normally open (NO), normally closed (NC) and to window mode. Thresholds and hysteresis can be set individually for each switching output. The default factory configuration of the two switching outputs is NO, with the thresholds set to 10% (Switch1) and 90% (Switch2). Hysteresis is set to 5% for both switching outputs. 5) Load resistance > 1 kOhm 6) 0%p refers to the specified minimum pressure and 100%p to the specified maximum pressure (see Table 3) 7) Accuracy is defined as the maximum deviation of the measurement value from the ideal characteristic curve at room temperature (RT) in %FSO, including the adjustment error (offset and span), nonlinearity, pressure hysteresis and repeatability. Nonlinearity is the measured deviation from the best fit straight line (BFSL) across the entire pressure range. Pressure hysteresis is the maximum deviation of the output value at any pressure within the specified range when this pressure is cycled to and from the minimum or maximum rated pressure. Repeatability is the maximum deviation of the output value at any pressure within the specified range after 10 pressure cycles. 8) The overall error is defined as the maximum deviation of the measurement value from the ideal characteristic curve in %FSO across the entire temperature range (-25…85°C). 9) With active switching outputs the current consumption increases by the output currents of the switching outputs (see "Specifications/Logic switching outputs”). 10) With the AMS 5105 starter kit software an adjustment of 0.1 %p (see note 6) is possible. 11) Media compatibility of pressure port 1 (for a description of port 1, see Figure 3): clean, dry gases, non-corrosive to silicon, RTV silicone rubber, gold (alkaline or acidic liquids can destroy the sensor). 12) Media compatibility of pressure port 2 (for a description of port 2, see Figure 3): fluids and gases non-corrosive to silicon, Pyrex, RTV silicone rubber. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |