Back Button AD9927BBCZ Datasheet HTML 48Page - Analog Devices AD9927BBCZ Datasheet HTML 49Page - Analog Devices AD9927BBCZ Datasheet HTML 50Page - Analog Devices AD9927BBCZ Datasheet HTML 51Page - Analog Devices AD9927BBCZ Datasheet HTML 52Page - Analog Devices AD9927BBCZ Datasheet HTML 53Page - Analog Devices AD9927BBCZ Datasheet HTML 54Page - Analog Devices AD9927BBCZ Datasheet HTML 55Page - Analog Devices AD9927BBCZ Datasheet HTML 56Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 52 / 100 page
background image
AD9927
Rev. 0 | Page 52 of 100
VD
REGISTER WRITE
A
MODE FIELD NUMBER
4 (DRAFT)
4 (DRAFT)
0 (STILL 1ST FIELD)
EXAMPLE MODE REGISTER CHANGE:
REGISTER WRITE A––WRITE TO MODE REGISTERS 0x2A, 0x2B, 0x2C TO SPECIFY
CHANGE FROM DRAFT MODE (FIELD4) TO STILL MODE (FIELD0/1/2/3).
ALSO WRITE TO VGA GAIN OR ANY NEW REGISTER VALUES NEEDED
FOR STILL FRAME OPERATION, SUCH AS NEW FIELD INFORMATION.
1 (STILL 2ND FIELD)
2
MODE UPDATE
MODE WRITE
Figure 65. Update of MODE Register, SCK Updated (Default Setting)
VD
REGISTER WRITE
AB
MODE FIELD NUMBER
4 (DRAFT)
4 (DRAFT)
0 (STILL 1ST FIELD)
EXAMPLE MODE REGISTER CHANGE:
REGISTER WRITE A––WRITE TO MODE REGISTERS 0x2A, 0x2B, 0x2C TO SPECIFY
CHANGE FROM DRAFT MODE (FIELD4) TO STILL MODE (FIELD0/1/2/3).
REGISTER WRITE B––WRITE TO VGA GAIN OR ANY NEW REGISTER VALUES NEEDED
FOR STILL FRAME OPERATION, SUCH AS NEW FIELD INFORMATION.
NOTES
1. NEW MODE INFORMATION IS UPDATED AT SECOND VD FALLING EDGE AFTER
SERIAL WRITE A.
1 (STILL 2ND FIELD)
2
MODE UPDATE
MODE WRITE
Figure 66. Update of MODE Register if Changed to VD-Updated Register
FIELD3
FIELD0
FIELD1
FIELD2
FIELD5
FIELD1
FIELD4
FIELD2
EXAMPLE 1:
TOTAL FIELDS = 3, FIRST FIELD = FIELD0, SECOND FIELD = FIELD1, THIRD FIELD = FIELD2
MODE SETTINGS:
0x2A = 0x3
0x2B = 0x820
0x2C = 0x0
EXAMPLE 2:
TOTAL FIELDS = 1, FIRST FIELD = FIELD3
MODE SETTINGS:
0x2A = 0x1
0x2B = 0x3
0x2C = 0x0
EXAMPLE 3:
TOTAL FIELDS = 4, FIRST FIELD = FIELD5, SECOND FIELD = FIELD1, THIRD FIELD = FIELD4, FOURTH FIELD = FIELD2
MODE SETTINGS:
0x2A = 0x4
0x2B = 0x11025
0x2C = 0x0
Figure 67. Using the MODE Registers to Select Field Timing



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com