| Electronic Components Datasheet Search |
|
SST38VF6402B Datasheet(PDF) 13 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
SST38VF6402B Datasheet(HTML) 13 Page - Microchip Technology |
|
13 / 56 page ![]() 2013 Microchip Technology Inc. Preliminary DS20005002D-page 13 SST38VF6401B / SST38VF6402B / SST38VF6403B / SST38VF6404B Program and Erase operations are prevented on the Boot Block when WP# is low. If WP# is left floating, it is internally held high via a pull-up resistor. When WP# is high, the Boot Block is unprotected, which allows Pro- gram and Erase operations on that area. 4.9.3 HARDWARE RESET (RST#) The RST# pin provides a hardware method of resetting the device to read array data. When the RST# pin is held low for at least TRP, any in-progress operation will terminate and return to Read mode. When no internal Program/Erase operation is in progress, a minimum period of TRHR is required after RST# is driven high before a valid Read can take place. See Figure 6-15 for more information. The interrupted Erase or Program operation must be re-initiated after the device resumes normal operation mode to ensure data integrity. 4.9.4 SOFTWARE DATA PROTECTION (SDP) The SST38VF6401B/6402B/6403B/6404B devices implement the JEDEC approved Software Data Protec- tion (SDP) scheme for all data alteration operations, such as Program and Erase. These devices are shipped with the Software Data Protection permanently enabled. See Table 5-2 for the specific software com- mand codes. All Program operations require the inclusion of the three-byte sequence. The three-byte load sequence is used to initiate the Program operation, providing opti- mal protection from inadvertent Write operations. SDP for Erase operations is similar to Program, but a six- byte load sequence is required for Erase operations. During SDP command sequence, invalid commands will abort the device to read mode within TRC. The con- tents of DQ15-DQ8 can be VIL or VIH, but no other value, during any SDP command sequence. The SST38VF6401B/6402B/6403B/6404B devices provide Bypass Mode, which allows for reduced Pro- gram and Erase command sequence lengths. In this mode, the SDP portion of Program and Erase com- mand sequences are omitted. See “Bypass Mode” on page 14 for further details. 4.10 Common Flash Memory Interface (CFI) The SST38VF6401B/6402B/6403B/6404B contain Com- mon Flash Memory Interface (CFI) information that describes the characteristics of the device. In order to enter the CFI Query mode, the system can write a one- byte sequence using a standard CFI Query Entry com- mand. Once the device enters the CFI Query mode, the system can read CFI data at the addresses given in Tables 5-4 through 5-7. The system must write the CFI Exit command to return to Read mode. Note that the CFI Exit command is ignored during an internal Program or Erase operation. See Table 5-2 for software command codes, Figures 6- 12 and 6-14 for timing waveform, and Figures 6-22 and 6-23 for flowcharts. 4.11 Product Identification The Product Identification mode identifies the devices as the SST38VF6401B, SST38VF6402B, SST38VF6403B, or SST38VF6404B, and the manu- facturer as Microchip. See Table 4-3 for specific address and data information. Product Identification mode is accessed through software operations. The software Product Identification operations identify the part, and can be useful when using multiple manufac- turers in the same socket. For details, see Table 5-2 for software operation, Figure 6-11 for the software ID Entry and Read timing diagram, and Figure 6-22 for the software ID Entry command sequence flowchart. While in Product Identification mode, the Read Block Protection Status command determines if a block is protected. The status returned indicates if the block has been protected, but does not differentiate between Vol- atile Block Protection and Non-Volatile Block Protec- tion. See Table 5-2 for further details. The Read-Irreversible Block-Lock Status command indicates if the Irreversible Block Command has been issued. If DQ0 = 0, then the Irreversible Lock command has been previously issued. In order to return to the standard Read mode, the soft- ware Product Identification mode must be exited. The exit is accomplished by issuing the software ID Exit command sequence, which returns the device to the Read mode. See Table 5-2 for software command codes, Figure 6-14 for timing waveform, and Figures 6- 22 and 6-23 for flowcharts. 4.12 Security ID The SST38VF6401B/6402B/6403B/6404B devices offer a Security ID feature. The Secure ID space is divided into two segments — one factory programmed 128 bit segment and one user programmable 248 word seg- ment. See Table 4-4 for address information. The first segment is programmed and locked at Microchip and TABLE 4-3: PRODUCT IDENTIFICATION Add Data Add Data Add Data Manufacturer’s ID 00H BFH Device ID SST38VF6401B 01H 227EH 0EH 220CH 0FH 2200H SST38VF6402B 01H 227EH 0EH 220CH 0FH 2201H SST38VF6403B 01H 227EH 0EH 2210H 0FH 2200H SST38VF6404B 01H 227EH 0EH 2210H 0FH 2201H |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |