7 / 16 page ![]() Ceraliquid CPS41D and CPS41 Endress+Hauser 7 Process Process temperature Version AB, AC: -15 to 80 °C (5 to 176 °F) Version BB, BC: 0 to 135 °C (32 to 275 °F) Process pressure (absolute) 1 to 11 bar (15 to 160 psi) if counterpressure applied via separate KCl vessel LCAUTION Pressurization of sensor due to prolonged use under increased process pressure Risk of injury from glass breakage ‣ Avoid excessive heating of such sensors if using them under reduced process pressure or under atmospheric pressure. ‣ When handling such sensors, wear protective goggles and suitable gloves. Minimum conductivity AB, BB version (1 diaphragm) Min. 5 μS/cm (flow reduced to minimum when KCl electrolyte is discharged) AC, BC version (3 diaphragms) Min. 0.1 μS/cm (flow assembly made of stainless steel with grounding; flow is stable and reduced to minimum when KCl electrolyte is discharged) pH range Version AB, AC: 1 to 12 pH Version BB, BC: 0 to 14 pH NOTICE Risk of damage to electrode ‣ Never use the electrode outside of the listed specifications! KCl consumption 1 2 3 B A 0 20 40 60 80 100 0 4 8 12 16 32 68 104 140 176 212 C A0028481 3 KCl consumption as a function of temperature A Consumption (ml/day) B Temperature (°C) C Temperature (°F) 1 800 mbar (11.6 psi) over pressure 2 400 mbar (5.8 psi) over pressure 3 100 mbar (1.5 psi) over pressure 1 2 3 A B 0 4 8 12 16 200 100 600 800 1000 1.5 2.9 5.8 8.7 11.6 14.5 C 400 A0028482 4 KCl consumption as a function of process pressure A Consumption (ml/day) B Over pressure relative to process (mbar) C Over pressure relative to process (psi) 1 Fluid temperature 80 °C (176 °F) 2 Fluid temperature 50 ° C (122 °F) 3 Fluid temperature 20 ° C (68 °F) The specified, approximated KCl consumption is based on electrodes with a single diaphragm. For electrodes with three diaphragms, KCl consumption is proportionately higher. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |