3 / 6 page ![]() show up as unstable display readings. When an input signal, assumed to be exactly zero volts, has a 1mV (0.001V) ground-loop induced offset, it is displayed as “0010” on a ±2V input-range meter! See Ap Note DMS- AN2 at http://www.murata-ps.com/data/meters/dms-an2.pdf describing power supply wiring and ground loop avoidance techniques. The DMS-40PC’s simplified schematic, shown in Figure 1, can be very useful when debugging a malfunctioning circuit, especially if the user has some knowledge of operational amplifiers (op amps). The meter’s high-impedance input consists of an op amp powered from a ±5Vdc power supply (the –5V is internally generated). Figure 1 shows that input signals applied to (–) INPUT LO and (+) INPUT HI must to be kept within the ±5V power-supply rails. Also note that only pin 11 has a current- limiting 909kΩ series resistor. High input voltages that have a common ground connection with pin 3 (5V RETURN) should only be applied to pin 11 ((+) INPUT HI) and never to pin 12. In these high-voltage cases, pin 12 should always be tied to pin 3 (5V RETURN). One of the simplified schematic’s more noteworthy features is that it shows some DMS-40PC internal voltage values and also that pin 3 is the meter’s zero-volt reference point — regardless of the type of power or signal source used. This is an important point to keep in mind when using digital multimeters to perform system-level measurements. The multimeter’s negative lead (usually the black one) must always be con- nected to pin 3 (5V RETURN). This is the only way accurate readings can be made, particularly if the meter is configured for a differential input and concerns arise regarding common-mode voltages. 1. Single-Ended Input Configurations: The DMS-40PC can measure single-ended signals with either positive or negative polarities. True single-ended inputs always have one of their two terminals at the same potential as the DMS-40PC’s 5V RETURN (pin 3). Single-ended inputs are usually derived from power supplies that have a common ground with the meter’s +5V supply. Figure 2 shows the recom- mended connections to be used with this type of input. Pin 12, (–) INPUT LO, is shown directly tied to ground. This connection to ground must be a separate wire or pc-board trace originating at VIN’s negative terminal. This hook-up will normally eliminate display instabilities and errors caused by ground-loop currents which can occur if (–) INPUT LO is tied to ground at, or near, pin 3. Hard wiring is preferable, however, you can exercise dynamic control over the location of the decimal point by employing drive circuits that are capable of sinking a minimum of 20mA at voltages less than +0.4 Volts. 6. Gain Adjust: There is a gain-adjust potentiometer on the back of each meter. It has approximately ±150 counts of adjustment range. Since these meters essentially have no zero/offset errors, a gain adjustment is effectively an overall accuracy adjustment. Though they may be performed at any point (except zero), accuracy adjust- ments are most effective when performed with higher level input signals. 7. Soldering Methods: All models in the DMS-40PC Series easily withstand most common wave soldering operations. We recom- mend, however, that you evaluate the effects your particular soldering techniques may have on the meter’s plastic case and high-precision electrical performance. We recommend the use of no-clean solders. 8. Suggested Mating Connectors: DMS-40PC Series meters are high-precision versatile devices that can be used in many applications requiring a 0 to 19,999 count digital display. The application circuits chosen for this section are ones that have historically received many inquiries. Every attempt has been made to ensure technical accuracy, and all of the following circuits have been prototyped and tested to ensure functionality. Please keep in mind, however, that real-world applications are seldom as straightforward as the approaches presented here. All inputs applied to DMS-40PC meters must be steady, dc values, otherwise the input itself may cause display instabilities. Due to their 4½ digit resolution, DMS-40PC meters must be wired with greater care than their 3½ digit counterparts. Correct power-supply and input-signal wiring — an absolute must! — helps eliminate ground-loop induced errors that Figure 2. Single-Ended Input Configuration 4. DISPLAY HOLD (Pin 9): For normal operation, this pin should be left open. To hold the meter’s last reading and display it continuously, tie pin 9 to ground (pin 3, 5V RETURN). 5. Decimal Point Placement: The location of the decimal point is user- selectable, and the decimal point control pins (DP1-DP4) are active low functions. Select the appropriate decimal point by tying pin 4, 5, 6 or 8 to pin 3 (5V RETURN). Unused decimal point location pins should be left open. Panel mounted: Connector housing Murata Power Solutions P/N 4320-01069-0 Terminal type Murata Power Solutions P/N 4400-01032-0 Crimping tool Murata Power Solutions P/N 39-2099000 Wire size 22 to 26 AWG Insulation diameter 0.062" (1.57mm) maximum Stripping length 0.100 to 0.125” (2.54 to 3.17mm) Board mounted: Socket Murata Power Solutions P/N 4320-01074-0 1 12 3 +5V SUP (–) IN LO 5V RET 120 VAC 11 (+) IN HI 6 DP1 + – AC to DC Converter VIN DMS-40PC-1-GS www.murata-ps.com/support DMS-40PC Series 4½ Digit, LED Display Digital Panel Voltmeters MPM_DMS-40PC.D04 Page 3 of 6 APPLICATIONS |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |