| Electronic Components Datasheet Search |
|
DSP56371 Datasheet(PDF) 39 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
DSP56371 Datasheet(HTML) 39 Page - Freescale Semiconductor, Inc |
|
39 / 68 page ![]() Reset, Stop, Mode Select, and Interrupt Timing DSP56371 Data Sheet, Rev. 4.1 Freescale Semiconductor 39 18 Delay from interrupt trigger to interrupt code execution. 10 xTC + 5 60.0 ns 19 Duration of level sensitive IRQA assertion to ensure interrupt service (when exiting Stop)2, 3 • PLL is active during Stop and Stop delay is enabled (OMR Bit 6 = 0) 9+(128K × TC) 704 — us • PLL is active during Stop and Stop delay is not enabled (OMR Bit 6 = 1) 25 × TC 138 — ns • PLL is not active during Stop and Stop delay is enabled (OMR Bit 6 = 0) 9+(128KxTC)+Tlock 5.7 ms • PLL is not active during Stop and Stop delay is not enabled (OMR Bit 6 = 1) (25 x TC)+Tlock 5ms 20 • Delay from IRQA, IRQB, IRQC, IRQD, NMI assertion to general-purpose transfer output valid caused by first interrupt instruction execution 10 x TC + 3.0 59.0 ns 21 Interrupt Requests Rate • ESAI, ESAI_1, SHI, DAX, Timer 12 x TC —— ns •DMA 8 x TC —— ns •IRQ, NMI (edge trigger) 8 x TC —— ns •IRQ (level trigger) 12 c TC —— ns 22 DMA Requests Rate • Data read from ESAI, ESAI_1, SHI, DAX 6 x TC —— ns • Data write to ESAI, ESAI_1, SHI, DAX 7 x TC —— ns •Timer 2 x TC —— ns •IRQ, NMI (edge trigger) 3 x TC —— ns Note: 1. When using fast interrupts and IRQA, IRQB, IRQC, and IRQD are defined as level-sensitive, timings 19 through 21 apply to prevent multiple interrupt service. To avoid these timing restrictions, the deasserted Edge-triggered mode is recommended when using fast interrupts. Long interrupts are recommended when using Level-sensitive mode. 2. For PLL disable, using external clock (PCTL Bit 13 = 0), no stabilization delay is required and recovery time will be defined by the OMR Bit 6 settings. For PLL enable, (if bit 12 of the PCTL register is 0), the PLL is shutdown during Stop. Recovering from Stop requires the PLL to get locked. The PLL lock procedure duration, PLL Lock Cycles (PLC), may be in the range of 0.5 ms. 3. Periodically sampled and not 100% tested 4. RESET duration is measured during the time in which RESET is asserted, VDD is valid, and the EXTAL input is active and valid. When the VDD is valid, but the other “required RESET duration” conditions (as specified above) have not been yet met, the device circuitry will be in an uninitialized state that can result in significant power consumption and heat-up. Designs should minimize this state to the shortest possible duration. Table 19. Reset, Stop, Mode Select, and Interrupt Timing (continued) No. Characteristics Expression Min Max Unit |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |