| Electronic Components Datasheet Search |
|
P1-32/I2/SVB Datasheet(PDF) 3 Page - Eaton All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
P1-32/I2/SVB Datasheet(HTML) 3 Page - Eaton All Rights Reserved. |
|
3 / 6 page ![]() 02/26/2015 207314 - HPL-ED2014 V9.0 EN 3 / 6 230 V P kW 7.5 400 V 415 V P kW 15 500 V P kW 18.5 690 V P kW 15 Rated operational current motor load switch 230 V Ie A 32 400 V 415 V Ie A 32 500 V Ie A 30 690 V Ie A 19.8 DC DC-1, Load-break switches L/R = 1 ms Rated operational current Ie A 32 Voltage per contact pair in series V 60 DC-23A, motor load switch L/R = 15 ms 24 V Rated operational current Ie A 25 Contacts Quantity 1 48 V Rated operational current Ie A 25 Contacts Quantity 2 60 V Rated operational current Ie A 25 Contacts Quantity 2 120 V Rated operational current Ie A 12 Contacts Quantity 3 Control circuit reliability at 24 V DC, 10 mA Fault probability HF < 10 -5, < 1 fault in 100000 operations Terminalcapacities Solid or stranded mm2 1 x (1,5 - 6) 2 x (1,5 - 6) Flexible with ferrules to DIN 46228 mm2 1 x (1 - 4) 2 x (1 - 4) Terminal screw M4 Max. tightening torque Nm 1.6 Technicalsafetyparameters: Notes B10d values as per EN ISO 13849-1, table C1 DatafordesignverificationaccordingtoIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation In A 32 Heat dissipation per pole, current-dependent Pvid W 1.8 Equipment heat dissipation, current-dependent Pvid W 0 Static heat dissipation, non-current-dependent Pvs W 0 Heat dissipation capacity Pdiss W 0 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Please enquire 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |