17 / 36 page ![]() 17-May-04 EPR-16 – LinkSwitch 2.75 W Charger/Adapter 8 Performance Data All measurements were performed at room temperature, 60 Hz input frequency unless otherwise specified. The output voltage was measured at the end of the output cable. Efficiency results therefore include output cable losses. Input power measurements were taken using a Yokogawa WT200 Single Phase Digital Power Meter. For the no-load measurement, the current scale was set to 10 mA. 8.1 Line and Load Regulation Regulation Curve 0 1 2 3 4 5 6 7 8 9 10 0 100 200 300 400 500 600 Load Current (mA) 85 VAC 115 VAC 190 VAC 230 VAC 265 VAC Figure 8 – Load Regulation at Selected Input Voltages. Page 17 of 36 Power Integrations Tel: +1 408 414 9660 Fax: +1 408 414 9760 www.powerint.com |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|