| Electronic Components Datasheet Search |
|
HYS64T64020HDL Datasheet(PDF) 31 Page - Qimonda AG |
|
|
|||||||||||||||||||||||||||||
HYS64T64020HDL Datasheet(HTML) 31 Page - Qimonda AG |
|
31 / 70 page ![]() Internet Data Sheet Rev. 1.1, 2006-10 31 03292006-5LTN-QML0 HYS64T[32/64/128]xxxHDL-[25F/2.5/3/3S/3.7/5]-B SO-DIMM DDR2 SDRAM Module TABLE 21 ODT AC Character. and Operating Conditions for DDR2-533 & DDR2-400 t AOFPD ODT turn-off (Power-Down Modes) t AC.MIN + 2 ns 2.5 t CK + tAC.MAX + 1 ns ns 1) t ANPD ODT to Power Down Mode Entry Latency 3 — nCK 1) t AXPD ODT Power Down Exit Latency 8 — nCK 1) 1) New units, ' t CK.AVG' and 'nCK', are introduced in DDR2-667 and DDR2-800. Unit 'tCK.AVG' represents the actual tCK.AVG of the input clock under operation. Unit 'nCK' represents one clock cycle of the input clock, counting the actual clock edges. Note that in DDR2-400 and DDR2-533, ' t CK' is used for both concepts. Example: tXP = 2 [nCK] means; if Power Down exit is registered at Tm, an Active command may be registered at Tm + 2, even if (Tm + 2 - Tm) is 2 × t CK.AVG+ tEPR.2PER(MIN). 2) ODT turn on time min is when the device leaves high impedance and ODT resistance begins to turn on. ODT turn on time max is when the ODT resistance is fully on. Both are measured from t AOND, which is interpreted differently per speed bin. For DDR2-667/800, tAOND is 2 clock cycles after the clock edge that registered a first ODT HIGH counting the actual input clock edges. 3) ODT turn off time min. is when the device starts to turn off ODT resistance. ODT turn off time max is when the bus is in high impedance. Both are measured from t AOFD. Both are measured from tAOFD, which is interpreted differently per speed bin. For DDR2-667/800,if tCK.AVG = 3 ns is assumed, t AOFD= 1.5 ns (0.5 × 3 ns) after the second trailing clock edge counting from the clock edge that registered a first ODT LOW and by counting the actual input clock edge. Symbol Parameter / Condition Values Unit Note Min. Max. t AOND ODT turn-on delay 2 2 t CK t AON ODT turn-on t AC.MIN t AC.MAX + 1 ns ns 1) 1) ODT turn on time min is when the device leaves high impedance and ODT resistance begins to turn on. ODT turn on time max is when the ODT resistance is fully on. Both are measured from t AOND, which is interpreted differently per speed bin. For DDR2-400/533, tAOND is 10 ns (= 2 x 5 ns) after the clock edge that registered a first ODT HIGH if t CK = 5 ns. t AONPD ODT turn-on (Power-Down Modes) t AC.MIN + 2 ns 2 t CK + tAC.MAX + 1 ns ns t AOFD ODT turn-off delay 2.5 2.5 t CK t AOF ODT turn-off t AC.MIN t AC.MAX + 0.6 ns ns 2) 2) ODT turn off time min. is when the device starts to turn off ODT resistance. ODT turn off time max is when the bus is in high impedance. Both are measured from t AOFD. Both are measured from tAOFD, which is interpreted differently per speed bin. For DDR2-400/533, tAOFD is 12.5 ns (= 2.5 x 5 ns) after the clock edge that registered a first ODT HIGH if t CK = 5 ns. t AOFPD ODT turn-off (Power-Down Modes) t AC.MIN + 2 ns 2.5 t CK + tAC.MAX + 1 ns ns t ANPD ODT to Power Down Mode Entry Latency 3 — t CK t AXPD ODT Power Down Exit Latency 8 — t CK Symbol Parameter / Condition Values Unit Note Min. Max. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |