| Electronic Components Datasheet Search |
|
MPC8280 Datasheet(PDF) 269 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPC8280 Datasheet(HTML) 269 Page - Freescale Semiconductor, Inc |
|
269 / 1386 page ![]() 60x Signals MPC8280 PowerQUICC II Family Reference Manual, Rev. 1 Freescale Semiconductor 7-11 Negated/High Impedance—Indicates that the MPC8280 does not need to retry the last address tenure. Timing Comments Assertion—May occur as early as the second cycle following the assertion of TS and must occur by the bus clock cycle immediately following the assertion of AACK if an address retry is required. Negation—Must occur during the second cycle after the assertion of AACK. 7.2.6 Data Bus Arbitration Signals The data bus arbitration signals have no meaning in internal-only mode. Like the address bus arbitration signals, data bus arbitration signals maintain an orderly process for determining data bus mastership. Note that there is no data bus arbitration signal equivalent to the address bus arbitration signal BR (bus request), because, except for address-only transactions, TS implies data bus requests. For a detailed description on how these signals interact, see Section 8.5.1, “Data Bus Arbitration.” 7.2.6.1 Data Bus Grant (DBG) The data bus grant signal (DBG) is an output/input on the MPC8280. 7.2.6.1.1 Data Bus Grant (DBG)—Input DBG an input when MPC8280 is configured to an external arbiter. The following are the state meaning and timing comments for DBG. State Meaning Asserted—Indicates that the MPC8280 may, with the proper qualification, assume mastership of the data bus. The MPC8280 derives a qualified data bus grant when DBG is asserted and DBB and ARTRY are negated; that is, the data bus is not busy (DBB is negated), and there is no outstanding attempt to perform an ARTRY of the associated address tenure. Negated—Indicates that the MPC8280 must hold off its data tenures. Timing Comments Assertion—May occur any time to indicate the MPC8280 is free to take data bus mastership. It is not sampled until TS is asserted. Negation—May occur at any time to indicate the MPC8280 cannot assume data bus mastership. 7.2.6.1.2 Data Bus Grant (DBG)—Output DBG signal is output when the MPC8280 configured to use the internal arbiter. Following are the state meaning and timing comments for the DBG signal. State Meaning Asserted—Indicates that the external device may, with the proper qualification, assume mastership of the data bus. A qualified data bus grant is defined as the assertion of DBG, negation of DBB, and negation of ARTRY. The requirement for the ARTRY signal is only for the address bus tenure associated with the data bus |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |