Electronic Components Datasheet Search
  New Zealand  ▼
ALLDATASHEET.CO.NZ

X  

TMP86CS25AFG Datasheet(PDF) 167 Page - Toshiba Semiconductor

Part # TMP86CS25AFG
Description  8 Bit Microcontroller
PDF  194 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TOSHIBA [Toshiba Semiconductor]
Direct Link  http://www.semicon.toshiba.co.jp/eng
Logo TOSHIBA - Toshiba Semiconductor

TMP86CS25AFG Datasheet(HTML) 167 Page - Toshiba Semiconductor

Back Button TMP86CS25AFG Datasheet HTML 163Page - Toshiba Semiconductor TMP86CS25AFG Datasheet HTML 164Page - Toshiba Semiconductor TMP86CS25AFG Datasheet HTML 165Page - Toshiba Semiconductor TMP86CS25AFG Datasheet HTML 166Page - Toshiba Semiconductor TMP86CS25AFG Datasheet HTML 167Page - Toshiba Semiconductor TMP86CS25AFG Datasheet HTML 168Page - Toshiba Semiconductor TMP86CS25AFG Datasheet HTML 169Page - Toshiba Semiconductor TMP86CS25AFG Datasheet HTML 170Page - Toshiba Semiconductor TMP86CS25AFG Datasheet HTML 171Page - Toshiba Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 167 / 194 page
background image
Page 157
TMP86CS25AFG
14.3.3 STOP and SLOW Mode during AD Conversion
When the STOP or SLOW mode is entered forcibly during AD conversion, the AD convert operation is sus-
pended and the AD converter is initialized (ADCCR1 and ADCCR2 are initialized to initial value.). Also, the
conversion result is indeterminate. (Conversion results up to the previous operation are cleared, so be sure to
read the conversion results before entering STOP or SLOW mode.) When restored from STOP or SLOW
mode, AD conversion is not automatically restarted, so it is necessary to restart AD conversion. Note that since
the analog reference voltage is automatically disconnected, there is no possibility of current flowing into the
analog reference voltage.
Example :After selecting the conversion time of 19.5
µs at 16 MHz and the analog input channel AIN3 pin, perform AD
conversion once. After checking EOCF, read the converted value and store the 8-bit data in address 009FH on
RAM.
; AIN SELECT
:
:
:
:
; Before setting the AD converter register, set each port reg-
ister suitably (For detail, see chapter of I/O port.)
LD
(ADCCR1), 00100011B
; Select AIN3
LD
(ADCCR2), 11011000B
; Select conversion time (312/fc) and operation mode
; AD CONVERT START
SET
(ADCCR1). 7
; ADRS = 1
SLOOP:
TEST
(ADCDR2). 5
; EOCF = 1 ?
JRS
T, SLOOP
; RESULT DATA READ
LD
A, (ADCDR1)
LD
(9FH), A



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com