| Electronic Components Datasheet Search |
|
K8DT-AS2CD Datasheet(PDF) 6 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
K8DT-AS2CD Datasheet(HTML) 6 Page - Omron Electronics LLC |
|
6 / 16 page ![]() K8DT-AS 6 Operation Methods Setting Ranges and Wiring Connections Connections Input Connect the input between the I1-COM, I2-COM, or I3-COM terminals, according to the input current. Malfunctions may occur if the input is connected to unused terminals and the Unit will not operate correctly. For the K8DT-AS3, the I1 terminal is not used. For the K8DT-AS2, the I3 terminal is not used. If using the OMRON K8AC-CT200L CT, connect to terminals k and l on the K8AC-CT200L. (Terminals kt and lt are not used.) Power Supply Connect the power supply to terminals A1 and A2. Outputs For a relay output, the SPDT contacts are output on terminals 11, 12, and 14. For a transistor output, the output is on terminals 11 and 14. The internal circuit of the transistor output is NPN, but application is possible for either a sinking or sourcing output. DIP Switch Settings The reset method, drive output method, and operating mode are set using the DIP switch located on the front of the Unit. For the K8DT-AS @, SW1 is not used. Note: Open the DIP switch cover to set the DIP switch. Keep the DIP switch cover closed while the power supply to the Relay is ON. Model Setting range Input type Wiring connections K8DT-AS1 2 to 20 mA AC/DC Direct input I1-COM 10 to 100 mA AC/DC Direct input I2-COM 50 to 500 mA AC/DC Direct input I3-COM K8DT-AS2 0.1 to 1 A AC/DC Direct input or commercially available CT I1-COM 0.5 to 5 A AC/DC I2-COM K8DT-AS3 10 to 100 A AC * OMRON CT I2-COM 20 to 200 A AC * OMRON CT I3-COM Note: The DC input terminals have no polarity. * The K8DT-AS3 is designed to be used in combination with the OMRON K8AC-CT200L Current Transformer (CT). (Direct input is not possible.) Single-phase power K8DT-AS3 K8AC- CT200L Current input or C (COM) A1 A2 I1 I2 I3 Load Power supply voltage 11 14 11 14 l k 12 Contact output Transistor output <For K8DT-AS3> load K8DT 11 Sinking In the case of sinking output applications 14 load K8DT 11 In the case of sourcing output applications 14 Sourcing SW3 DIP switch pins SW2 SW1 SW4 DIP Switch Functions Note: All pins are set to OFF by default. Pin ON ❍↑ OFF ●↓ Resetting method Automatic reset Not used. ❍ --- --- Manual reset ● --- --- Output drive method Normally closed --- ❍ --- Normally open --- ● --- Operating mode Undercurrent --- --- ❍ Overcurrent --- --- ● 1 ON OFF 2 3 4 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |