MP6650 Datasheet(PDF) 12 Page - Monolithic Power Systems

Part # MP6650
Description  Single-Phase, BLDC Motor Driver with Integrated Hall Sensor in a TSOT23-6 Package
PDF  24 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MPS [Monolithic Power Systems]
Direct Link  http://www.monolithicpower.com
Logo MPS - Monolithic Power Systems

MP6650 Datasheet(HTML) 12 Page - Monolithic Power Systems

Back Button MP6650 Datasheet HTML 8Page - Monolithic Power Systems MP6650 Datasheet HTML 9Page - Monolithic Power Systems MP6650 Datasheet HTML 10Page - Monolithic Power Systems MP6650 Datasheet HTML 11Page - Monolithic Power Systems MP6650 Datasheet HTML 12Page - Monolithic Power Systems MP6650 Datasheet HTML 13Page - Monolithic Power Systems MP6650 Datasheet HTML 14Page - Monolithic Power Systems MP6650 Datasheet HTML 15Page - Monolithic Power Systems MP6650 Datasheet HTML 16Page - Monolithic Power Systems Next Button
Zoom Inzoom in Zoom Outzoom out
 12 / 24 page
background image
MP6650
– SINGLE-PHASE, BLDC MOTOR DRIVER WITH INTEGRATED HALL SENSOR
MP6650 Rev. 1.0
www.MonolithicPower.com
12
11/14/2019
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2019 MPS. All Rights Reserved.
Off
During
this
time,
OUT1
remains
at
high
impedance, and OUT2 remains low. The time
duration is adaptive from 0 degrees to 45
degrees. In steady state, this function block
maintains the phase lock of the Hall output
falling edge and winding current zero-crossing
edge.
When the Hall output is at a low interval, the
conducting phase changes, but the switching
sequence remains the same.
PWM Input Starting Duty
The
start-up
duty
of
the
PWM
input
is
determined by the 14H register value set by the
register. An example is below:
SPD_ZERO = 1, 14H = 0x20 (12.5%)
When the input duty is less than 12.5%, the fan
maintains a zero speed. When the input duty is
above 13.7% (hysteresis 1.2%), the fan starts
rotating. The speed is based on the 00h to 08h
duty cycle setting (see Figure 5).
PWM Input Duty
Output
Duty
0
100%
Duty_Starting
(14h)
Figure 5: Configurable Speed Curve
SPD_ZERO = 0, 14H = 0x20 (12.5%)
When the input duty is less than 12.5%, the fan
keeps a minimum PWM output duty cycle set
by the 00h to 08h register setting (see Figure
6).
PWM Input Duty
Output
Duty
0
100%
Min. Duty
Duty_Starting
(14h)
Figure 6: Configurable Speed Curve
Protection Circuits
The MP6650 is fully protected against over-
voltage, under-voltage, over-current, and over-
temperature events. It also has input reverse
protection.
Over-Current Protection (OCP)
The MP6650 protects against internal overload
and short circuit by detecting the current flowing
through each MOSFET. If the current flowing
through any MOSFET exceeds the over-current
protection (OCP) threshold after about 1.5µs of
blanking
time,
that
MOSFET
turns
off
immediately. After the lock-retry time delay
(default
3.6s),
the
bridge
re-enables
automatically.
Overload Current Limit
During normal switching, if the current flowing
through the high-side MOSFET (HS-FET) of the
H-bridge exceeds the threshold set by the
SUCL register bits after about 1.5µs of blanking
time, the HS-FET turns off immediately. The
HS-FET
resumes
switching
in
the
next
switching cycle. The overload current limit is
configurable with 0.7A, 1.1A, 1.6A, or 2A. The
default limit it 1.6A.
Thermal Shutdown
Thermal monitoring is also integrated into the
MP6650. If the die temperature exceeds 150°C,
the MOSFETs of the switching half-bridge turn
off. Once the die temperature drops to a safe
temperature, operation resumes automatically.
Under-Voltage Lockout (UVLO)
If at any time VCC falls below the under-voltage
lockout (UVLO) threshold voltage, all circuitry in
the device disables, and the internal logic
resets. Operation resumes when VCC rises
above the UVLO threshold.
Rotor Deadlock Protection (RD)
The MP6650 detects the internal Hall signal
and outputs a deadlock indication signal to the
FG/RD pin if the FGRD bit is set to 11. If the IC
cannot see the Hall signal edge change during
the 0.6s detection time, the low-side MOSFETs
of the H-bridge turn on. After 1.8s, 2.4s, 3s, or
3.6s of lock-retry time (depending on the
RLOCK_SEL bit
’s setting), the IC attempts to
start up again automatically. FG/RD pin outputs
again only after three Hall signal edges are



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com