| Electronic Components Datasheet Search |
|
LM6584MA/NOPB Datasheet(PDF) 19 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
LM6584MA/NOPB Datasheet(HTML) 19 Page - Texas Instruments |
|
19 / 33 page ![]() + - AMPLIFIER UNDER TEST +6.5V -6.5V RLOAD 1k: 50: 2V 0 0 -2V OR HP 8082 PULSE GENERATOR TEK 7633 STORAGE SCOPE + TEK 7S14 SAMPLING INPUT VOUT t VF 0 TSR TSET TPD LM6584 www.ti.com SNOSA44C – MAY 2003 – REVISED MARCH 2013 Another important specification for Gamma Buffers is small signal bandwidth and slew rate. When column drivers select which voltage levels are written to a row of pixels, their internal DACs inject current spikes into the Gamma Lines. This generates voltage transients at the Gamma Buffer outputs, and they should settle-out in less than 1 μs to insure a steady output voltage from the column drivers. Typically, these transients have a maximum amplitude of 2V, so a gamma buffer must have sufficient bandwidth and slew rate to recover from a 2V transient in 1 μs or less. Figure 35. Large Signal Transient Response of an Operational Amplifier Figure 35 illustrates how an op amp responds to a large-signal transient. When such a transient occurs at t = 0, the output does not start changing until TPD, which is the op amp’s propagation delay time (typically 20ns for the LM6584). The output then changes at the op amp’s slew rate from t = TPD to TSR. From t = TSR to TSET, the output settles to its final value (VF) at a speed determined by the op amp’s small-signal frequency response. Although propagation delay and slew limited response time (t = 0 to TSR) can be calculated from data sheet specifications, the small signal settling time (TSR to TSET) cannot. This is because an op amp’s gain vs. frequency has multiple poles, and as a result, small-signal settling time can not be calculated as a simple function of the op amp’s gain bandwidth. Therefore, the only accurate method for determining op amp settling time is to measure it directly. Figure 36. Gamma Buffer Settling Time Test Circuit The test circuit in Figure 36 was used to measure LM6584 settling time for a 2V pulse and 1k Ω load, which represents the maximum transient amplitude and output load for a gamma buffer. With this test system, the LM6584 settled to within ±30mV of 2V pulse in approximately 170ns. Settling time for a 0 to –2V pulse was slightly less, 150ns. These values are much smaller than the desired response time of 1 μs, so the LM6584 has sufficient bandwidth and slew rate for regulating gamma line transients. Copyright © 2003–2013, Texas Instruments Incorporated Submit Documentation Feedback 19 Product Folder Links: LM6584 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |