| Electronic Components Datasheet Search |
|
MA710 Datasheet(PDF) 21 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MA710 Datasheet(HTML) 21 Page - Monolithic Power Systems |
|
21 / 27 page ![]() MA710 – 12-BIT, DIGITAL ANGLE SENSOR WITH ABZ & PWM OUTPUTS MA710 Rev. 1.0 www.MonolithicPower.com 21 9/27/2017 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2017 MPS. All Rights Reserved. Figure 22: Relation between the Error Measured with BCT = 0 and the Magnet Ratio k Sensor Orientation From the dot marked on the package, it is possible to know whether the radial field is aligned with the sensor coordinate X or Y (see Figure 23). Figure 18: Package Top View with X and Y Axes Determine which axis needs to be reduced (see the qualitative field distribution around a ring in Figure 19). For instance, with the arrangement depicted in Figure 23, the field along the sensor Y direction is tangential and weaker. The X-axis should be reduced (ETX = 1 and ETY = 0). Note that if both ETX and ETY are set to 1, the current bias is reduced in both directions the same way (i.e.: without side-shaft correction) (see Table 14). Table 14: Trimming Direction Parameters ETX Enable Trimming of the X-Axis 0 Disabled 1 Enabled ETY Enable Trimming of the Y-Axis 0 Disabled 1 Enabled Magnetic Field Thresholds The magnetic flags (MGL and MGH) indicate that the magnetic field at the sensor position is out a range defined by the lower (MGLT) and upper magnetic field thresholds (MGHT) (see Figure 24). Figure 19: MGH and MGL Signals as a Function of the Field Strength MagHys, the typical hysteresis on the signals MGH and MGL is 6mT. The MGLT and MGHT thresholds are coded on three bits and stored in register 6 (see Table 15). Table 15: Register 6 Register 6 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 MGLT MGHT - - The 3-bit values of MGLT and MGHT correspond to the magnetic field (see Table 16). Table 16: MGLT and MGHT: Binary to mT Relation MGLT or MGHT (8) Field threshold in mT (7) From low to high magnetic. field From high to low magnetic. field 000 26 20 001 41 35 010 56 50 011 70 64 100 84 78 101 98 92 110 112 106 111 126 120 NOTES: 7) Valid for VDD=3.3V. If different then field threshold is scaled by the factor VDD/3.3V. 8) MGLT can have a larger value than MGHT. The alarm flags MGL and MGH are available to be read in register 27 (bit 6, bit 7), and their logic state is also given at the digital output pins 11 and 16. 1 1.5 2 2.5 3 3.5 4 4.5 5 0 5 10 15 20 25 30 35 40 E (deg) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |