| Electronic Components Datasheet Search |
|
L99UDL01 Datasheet(PDF) 58 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99UDL01 Datasheet(HTML) 58 Page - STMicroelectronics |
|
58 / 88 page ![]() Programmers guide L99UDL01 58/88 DS12511 Rev 5 If OUT1 and OUT2 are grouped (GRP1_2 bit is set in register 03H) OUT1_on can be used to command these two outputs on. OUT2_on will be ignored if used. In normal mode, all overridden outputs (internal and external) will experience a ~6us pause at each write access to register 01h that does not set the OUT_ON control bit. In emergency mode, all overridden outputs (internal and external) will experience a ~10 µs pause at each write access to register 01h regardless of the OUT_ON control bit value. Once back in normal mode from the emergency one, the behavior will remain the one described in emergency mode, unless the overridden outputs are disabled and then enabled again. EMCYx Emergency mode overrides any current actuation command in progress and drives outputs according to the programmed values in the registers. If OUT_ON is low on the rising edge of CSN then all timed actuation activity (if a timed actuation is in progress) will stop and wait for an actuation. While in Emergency mode the status bits (STAT[1:0]) will be automatically cleared whenever there is a write to CR01H. This command also overrides all protections such as thermal shutdown and overcurrent latch off. In Emergency mode the device will not latch off if an overcurrent threshold is exceeded. Instead of latching off the driver and reporting a fault the output will continue to retry as in Normal mode. All faults will be reported while not acted upon. Emergency mode is initiated when a (1, 0) is entered in the EMCY bits. All other EMCY bit configurations result in Normal mode. Emergency mode is exited by initiating another actuation where the EMCY bits are different from (1,0) or because of V3V3RST event. At the initiation of an emergency mode timed actuation a ~10 µs pause will be experienced on all overridden outputs (internal and external). In case of indefinite braking, at the initiation of an emergency mode timed actuation a ~10 µs pause will be experienced on all outputs (internal overridden, external overridden and time actuated) EXTx_LSD, EXTx_HSD These bits determine the polarity of an output, i.e. they specify which is the driver switched on, High Side or Low Side. External drivers cannot be PWMmed. Table 31. 01H emergency command description EMGCY bits Bit 1 Bit 0 Mode 0 0 Normal mode 0 1 Normal mode 1 0 Emergency mode 1 1 Normal mode |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |