1 / 1 page ![]() UR-Series - UL1077 Recognized Supplementary Protector - 3 pole C-Trip Standard Pack: 12 Weight: 0.3A - 32A 1.75kg (3.86 lb.) 40A - 63A 2.07kg (4.56 lb.) 3 Pole 52.5 mm 68.4 mm 44 mm 30.5 mm 44 mm 37.5 mm 25.5 mm 14.5 mm 84 67 Rated Type/ Rated Current Cat. No. Voltage 0.5A 3C05UR 480Y/277V AC 1.0A 3C1UR 480Y/277V AC 2.0A 3C2UR 480Y/277V AC 3.0A 3C3UR 480Y/277V AC 4.0A 3C4UR 480Y/277V AC 5.0A 3C5UR 480Y/277V AC 6.0A 3C6UR 480Y/277V AC 8.0A 3C8UR 480Y/277V AC 10A 3C10UR 480Y/277V AC 12A 3C12UR 480Y/277V AC 13A 3C13UR 480Y/277V AC 15A 3C15UR 480Y/277V AC 16A 3C16UR 480Y/277V AC 20A 3C20UR 480Y/277V AC 25A 3C25UR 480Y/277V AC 30A 3C30UR 480Y/277V AC 32A 3C32UR 480Y/277V AC 40A 3C40UR 480Y/277V AC 50A 3C50UR 480Y/277V AC 60A 3C60UR 480Y/277V AC 63A* 3C63UR 480Y/277V AC *63A is not UL Recognized. 10-3 4x10-3 10-2 4x10-2 10-1 0.4 1 4 10 1 4 10 40 60 12 3 4 5 68 10 20 40 100 Multiple of Rated Current Thermal Overload “Must Trip” < 1 hr = 145% RC “Must Not Trip” > 1 hr = 113% RC 1.13-1.45xI N 0.5A Through 10A Rated Current 10-3 4x10-3 10-2 4x10-2 10-1 0.4 1 4 10 1 4 10 40 60 12 3 4 5 68 10 20 40 100 Multiple of Rated Current Thermal Overload “Must Trip” < 1 hr = 145% RC “Must Not Trip” > 1 hr = 113% RC 1.13-1.45xI N 12A Through 63A Rated Current Short Circuit Withstand Ratings for R-Series Supplementary Protector “C” Magnetic Trip Parameters Rated current 0.5A to 63A. 1. Hold for a minimum of 100ms at surge of 5 times rated current. 2. Trip in under 100ms at 10 times rated current. UR - Series Voltage Rating Short Circuit Withstand Rating Calibration Temperature Ambient Temperature Storage Temperature Terminal Torque (min/max) Electrical Life Mechanical Life Vibration Resistance Resistance to mechanical shocks 0.5-60A / 480Y/277V AC 0.5 - 10A (RC): 10 kA with no back-up fuse 8 - 63A (RC): 10 kA with UL-listed Class J back-up fuse; 5 kA with no back-up fuse 30ºC (86ºF) -25ºC to +55ºC (-13ºF to 131ºF ) -40ºC to +70ºC (-40ºF to 158ºF ) 2 Nm (17.7 lb.in.) / 2.5Nm (22.2 lb.in) 6000 switching cycles ON/ OFF 10000 switching cycles ON/ OFF > 15g according to DIN EN 60069-2-59 during a load with 1.05 x IN 25g @ 11ms Backup Protection Trip Amp UL-Listed No Backup Fuse Curve Range Class J Fuse Required up to 10kA up to: All 0.5 - 10A 70A 10kA All 12 - 60A 4xRC* 5kA *up to nearest rated current UL Recognized C US E137915 Three Pole |
Similar Part No. - 3C2UR |
|
Similar Description - 3C2UR |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |