| Electronic Components Datasheet Search |
|
M36W432B Datasheet(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M36W432B Datasheet(HTML) 13 Page - STMicroelectronics |
|
13 / 57 page ![]() 13/57 M36W432T, M36W432B Read Electronic Signature Command. The Read Electronic Signature command reads the Manufacturer and Device Codes and the Block Locking Status, or the Protection Register. The Read Electronic Signature command consists of one write cycle, a subsequent read will output the Manufacturer Code, the Device Code, the Block Lock and Lock-Down Status, or the Protec- tion and Lock Register. See Tables 4, 5 and 6 for the valid address. Read CFI Query Command. The Read Query Command is used to read data from the Common Flash Interface (CFI) Memory Area, allowing pro- gramming equipment or applications to automati- cally match their interface to the characteristics of thedevice. OneBus Writecycleis requiredtois- sue the Read Query Command. Once the com- mand is issued subsequent Bus Read operations read from the Common Flash Interface Memory Area. See Appendix B, Common Flash Interface, Tables 28, 29, 30, 31, 32 and 33 for details on the information contained in the Common Flash Inter- face memory area. Block Erase Command. TheBlock Erasecom- mand canbeusedtoerase ablock. It sets all the bits within the selected block to ’1’. All previous data in the block is lost. If the block is protected then the Erase operation will abort, the data in the block will not be changed and the Status Register will output the error. Two Bus Write cycles are required to issue the command. s The first bus cycle sets up the Erase command. s The second latches the block address in the internal state machine and starts the Program/ Erase Controller. If the second bus cycle is not Write Erase Confirm (D0h), Status Register bits b4 and b5 are set and the command aborts. Erase aborts if Reset turns to VIL. As data integrity cannot be guaranteed when the Erase operation is aborted, the block must be erased again. During Erase operations the memory will accept the Read Status Register command and the Pro- gram/Erase Suspend command, all other com- mands will be ignored. Typical Erase times are given in Table 7, Program, Erase Times and Pro- gram/Erase Endurance Cycles. See Appendix C, Figure 28, Erase Flowchart and Pseudo Code, for a suggested flowchart for using the Erase command. Program Command. The memory array can be programmed word-by-word. Two bus write cycles are required to issue the Program Command. s The first bus cycle sets up the Program command. s The second latches the Address and the Data to be written and starts the Program/Erase Controller. During Program operations the memory will ac- cept the Read Status Register command and the Program/Erase Suspend command. Typical Pro- gram times are given in Table 7, Program, Erase Times and Program/Erase Endurance Cycles. Programming aborts if Reset goes to VIL. As data integrity cannot be guaranteed when the program operation is aborted, the block containing the memory location must be erased and repro- grammed. See Appendix C, Figure 25, Program Flowchart and Pseudo Code, for the flowchart for using the Program command. Double Word Program Command. This feature is offered to improve the programming throughput, writing a page of two adjacent words in paral- lel.The two words must differ only for the address A0. Programming should not be attempted when VPPF is not at VPPH. The command can be execut- ed if VPPF is below VPPH but the result is not guar- anteed. Three bus write cycles are necessary to issue the Double Word Program command. s The first bus cycle sets up the Double Word Program Command. s The second bus cycle latches the Address and the Dataof the first wordtobe written. s The third bus cycle latches the Address and the Data of the second word to be written and starts the Program/Erase Controller. Read operations output the Status Register con- tent after the programming has started. Program- ming aborts if Reset goes to VIL. As data integrity cannot be guaranteed when the program opera- tion is aborted, the block containing the memory location must be erased and reprogrammed. See Appendix C, Figure 26, Double Word Pro- gram Flowchart and Pseudo Code, for the flow- chart for using the Double Word Program command. Clear Status Register Command. The Clear Status Register command can be used to reset bits 1, 3, 4 and 5 in the Status Register to ‘0’. One bus write cycle is required to issue the Clear Sta- tus Register command. The bits in the Status Register do not automatical- ly return to ‘0’ when a new Program or Erase com- mand is issued. The error bits in the Status Register should be cleared before attempting a new Program or Erase command. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |