11 / 19 page ![]() Application Notes For technical support and further information visit http://power.ti.com Figure 3-2 Figure 3-3 Vo (2 V/Div) Iin (1 A/Div) Vinh (10 V/Div) HORIZ SCALE: 5 ms/Div Power-Up Characteristics When configured per the standard application, the PTH12000x power modules produce a regulated out- put voltage whenever of a valid input voltage is applied from Vin (pin 2), with respect to GND (pin 1). During the power-up period, internal soft-start circuitry slows the rate that the output voltage rises. This reduces the in-rush current drawn from the input source. The soft-start cir- cuitry also introduces a short time delay (typically 12 ms) into the power-up characteristic. The delay is from the point that a valid input source is recognized, to the initial rise of the output voltage. Figure 3-1 shows the power- up characteristic of the PTH12000W with the output voltage set to 5-V. The waveforms were measured with a 2-A resistive load. The initial rise in input current when the input voltage first starts to rise is the charge current drawn by the input capacitors. Figure 3-1 Vin (5 V/Div) Vo (5 V/Div) Iin (2 A/Div) HORIZ SCALE: 5 ms/Div Over-Current Protection For protectection against load faults, this series incorpo- rates output over-current protection. Applying a load that exceeds the module’s over-current threshold will cause the regulated output to shut down. Following shut down the module will periodically attempt to recover by initi- ating a soft-start power-up. This is often described as a “hiccup” mode of operation, whereby the module con- tinues in the cycle of successive shut down and power up until the load fault is removed. During this period, the average current flowing into the fault is significantly reduced. Once the fault is removed, the module auto- matically recovers and returns to normal operation. Output On/Off Inhibit The inhibit control (pin 3) is used wherever there is a requirement to turn off the regulator output while input power is applied. PTH12000 Series PTH12000W VIN 4 5 2 3 L O A D CIN 100 µF Co1 100 µF 1 =Inhibit GND GND VOUT Q1 BSS138 RSET 280 1% 1 The power modules function normally when the Inhibit pin is left open-circuit, providing a regulated output whenever a valid source voltage is connected to Vin with respect to GND. Figure 3-2 shows the typical application of the inhibit function. Note the discrete transistor (Q1). The Inhibit pin has its own internal pull-up to Vin potential. An open-collector or open-drain device is recommended to control this input. Turning Q1 on applies a low voltage to the inhibit control and disables the output of the module. If Q1 is then turned off, the module will execute a soft-start power-up. A regulated output voltage is produced within 25 msec. Figure 3-3 shows the typical rise in both the output volt- age and input current, following the turn-off of Q1. The turn off of Q1 corresponds to the rise in the waveform, Vinh. The waveforms were measured with a 5-V output and 2-A resistive load. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |