  CS-LDTC09 Datasheet HTML 1Page - Wavelength Electronics, Inc. CS-LDTC09 Datasheet HTML 2Page - Wavelength Electronics, Inc. CS-LDTC09 Datasheet HTML 3Page - Wavelength Electronics, Inc. CS-LDTC09 Datasheet HTML 4Page - Wavelength Electronics, Inc. CS-LDTC09 Datasheet HTML 5Page - Wavelength Electronics, Inc. CS-LDTC09 Datasheet HTML 6Page - Wavelength Electronics, Inc.  
Zoom Inzoom in Zoom Outzoom out
 4 / 6 page
background image
Case Study CS-LDTC09 Rev. A
Page 4
© 2021 • Sales & Technical Support: (406) 587-4910 • email: sales@teamWavelength.com • web: www.teamWavelength.com
Figure 4. Principle
diagram
of
high-sensitivity
detection of harmful gases in livestock based on TDLAS2
length of the light increases the sensitivity of gas detection
due to the Beer-Lambert law which directly relates
absorption to path length.
Once again a distributed feedback laser is used at 5 mW
output power and a central wavelength of 1512 nm. A
butterfly pigtail package is used for precision control of
laser temperature using the thermoelectric cooler inside
the package. The photoelectric detection circuit is also
crucial to the TDLAS technique. One of the most critical
pieces, relating to the performance of the signal detection
and absorption spectum, is the photodiode. Photodiodes
with low temperature drift, minimal dark noise, low junction
capacitance, and high responsitivity are necessary for
sensitive measurements.1 Controlling the laser current and
temperature for stable tuning and output is also necessary
for accurate results.
RESULTS
Both studies provide a theoretical basis and technical
support for emission detection and control in livestock
housing. While differing slightly in setup and technique,
these spectroscopy methods enable high sensitivity
detection of low concentration ammonia and potentially
other harmful gases produced in agricultural settings.
The OPLAS setup resulted in an advantageous technique
in high dust, high temperature, and high humidity
environments without the need for a gas absorption cell.
The length between the collimator and retroreflector was
2 m, making the total path length traveled by the light 4 m.
The laser diode was scanned and modulated between the
current range of 55 - 85 mA using a 5 Hz low frequency
sawtooth wave. Experiments in the study showed that the
OPLAS detection system can detect the voltage absorption
peak caused by ammonia absorption of the laser beam
within the 4 m open path with extremely high sensitivity.2
The TDLAS setup did not allow for direct absorption signal
detection in the gas absorption cell. However, the harmonic
absorption signal can be recorded by an oscilloscope. This
type of detection enables more sensitive and accurate
results compared to direct absorption signal detection.
The equipment and the ammonia detection can be seen
in
Figure 5 below. The direct absorption signal follows the
laser driver signal without any absorption peak or events.
The harmonic absorption signal shows an absorption peak
at a certain wavelength along the current scanning ramp.
Figure 5. Real equipment photo of ammonia detection
based on TDLAS with long light path.2
The laser wavelength was scanned and tuned using a
5 Hz low frequency sawtooth wave and a 5 kHz frequency
modulation sinusoidal signal input through the laser driver.
This experiment proved the usefulness of tunable lasers
in ammonia gas detection in livestock housing and similar
applications. The system recorded detecting harmonic
signals created by ammonia with a concentration of
lower than 5 ppm, showing high sensitivity for livestock
environments.
This sensitivity allows the detection of low levels of
ammonia, which start to affect livestock and human workers
at concentrations of 10 - 30 ppm. The TDLAS technique
enables precise detection of ammonia before affects can be
severe and harmful around 50 ppm.
Future research and experiments will further prove the
effectiveness of OPLAS and TDLAS and other types of
laser absorption spectroscopy in the field of agriculture.
Better detection of NH
3 and other harmful gases could lead
the way for safer and healthier environments for livestock
and poultry. These, along with assessments of housing
types, ventilation systems, and flooring types, can enable
accurate support for intelligent air quality detection and
control in livestock and poultry housing.



Html Pages

1 2 3 4 5 6


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com