| Electronic Components Datasheet Search |
|
RF2000 Datasheet(PDF) 1 Page - TOKYO KEISO CO.,LTD. |
|
|
|||||||||||||||||||||||||||||
RF2000 Datasheet(HTML) 1 Page - TOKYO KEISO CO.,LTD. |
|
1 / 4 page ![]() OUTLINE RF2000 is a system that measures the air flow velocity to the engine radiator. The rotation frequency of a propeller sensor is measured by an infrared sensor attached to the propeller sensor. The signal from the infrared sensor is transmitted via an electrical cable to a converter for measuring the radiator air flow velocity and then converted to air flow velocity. A single conver ter can measure air flow velocity at 16 channels. The converter is also equipped with functions for displaying the air flow velocity and frequency, outputting an analog voltage, and performing RS-485 and CAN communication. For RS-485 communication, up to four converters can be connected to enable simultaneous data collection on a ma ximum of 64 channels. Furthermore, the dedicated measurement software TIC Wind-LV can be used to set the measurement interval and number of measurements, to collect air flow velocity data, and to output an average value for the air flow velocity. Converter settings can be changed from a computer. For CAN communication, up to four converters can be connected to enable collection of air flow velocity data. Also, driving tests can be performed by mounting the entire system in a vehicle. FEATURES ❑ Compact sensors A thin and light-weight sensor with thickness of only 10 mm can be installed at a narrow space such as between a radiator and condenser. ❑ Accurate directional measurement The propeller sensor with its axis aligned parallel to the air flow direction, allows accurate measurement of the flow velocity along the perpendicular to the radiator, neglecting the flow from the other directions. Other types of sensor such as thermal type or pressure type tends to measure flow from all other directions. ❑ Low pressure loss The pressure loss caused by the propeller is approximately 0.1 kPa (at the velocity of 20 m/s). This is very small when compared to the pressure loss of the radiator. ❑ Connected to electric cables Electric cables used to connect the propeller sensors and converter are flexible, resistant to low temperatures, and are easier to handle compared to optical fiber cables. ❑ More channels One unit of the RR5000D/RR5100D is capable of measuring 16 channels. ❑ RS-485 Four converters connected in a daisy chain can simultaneously collect data from up to 64 channels. The settings of the converters can be changed from a PC. ❑ CAN communication Four converters connected in a daisy chain can simultaneously collect data from up to 64 channels. The communication data are transformed to air flow velocity values based on the DBC file. Radiator air flow measurement system RF2000 RR5000D/RR5100D Converter for Infra- red Sensors RF2000 SYSTEM SPECIFICATIONS (1) Converter RR5000D/RR5100D converter for infrared sensors Power supply 12 to 24 V DC ±10% Display 2 lines in a LCD Measuring channel, air flow velocity and frequency Operation key CH UP, CH DOWN, SHIFT, INC., ENT., and MOVE total 6 Setting function Low level cut-off, Moving average, Air-flow conversion factors, Full scale air flow velocity, Linearize setting, Start channel setting,End channel setting,Display update cycle, RS-485 communication unit address/ID address, CAN communication speed Analog output 0 to 5 VDC, 16 channels Load resistance 100 k Ω or more Accuracy Frequency conversion accuracy: ± 1 Hz Analog output accuracy: ±0.6% of the reading ±0.01V (Based on display value) Communi- cation RS-485 and CAN communication functions Temperature range 5 to 60°C (2) Vane anemometer (propeller sensor) RS-1050-IR/RS-1150-IR infrared sensor Form Dimension : Approx. 69 mm including lugs for installation, Five vanes Cable length : 6 m Measuring range 0.4 to 30 m/s Accuracy ±(1% of reading + 0.05 m/s) at the range of 0.4 to 20 m/s Temperature range -40 to 120°C Without condensation of moisture or freezing (Maximum continuous operating temperature is 100°C) RS-1038-IR/RS-1138-IR infrared sensor Form Dimension : Approx. 42 mm including lugs for installation, Five vanes Cable length : 6 m Measuring range 0.5 to 30 m/s Accuracy ±(1.5% of reading + 0.05 m/s) at the range of 0.5 to 20 m/s Temperature range -40 to 120°C Without condensation of moisture or freezing (Maximum continuous operating temperature is 100°C) (3) Communication and data processing software “TIC Wind-LV” RW2000 (Dedicated for the RF2000) System requirement Windows 7 SP1 or later operation systems Communi- cation RS-485 Function The air flow data for each channel is collected. Data are measured multiple times (1 to 99999 times) at a fixed time interval (1 to 9999 seconds) and recorded in a CSV file. Parameter settings in the converter are changed. TG-F1123-E04 5th edition Nov 2020 K 1st edition Jul 2015 K |
Similar Part No. - RF2000 |
|
Similar Description - RF2000 |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |