4 / 7 page ![]() Product Specification 2R-8x6 series GAS DISCHARGE TUBS Circuit Protection www.yageo.com Feb. 02, 2021 V.1 Electrical Characteristics Part Number DC Spark-over Voltage Maximum Impulse Spark-over Voltage Nominal Impulse Discharge Current Alternating Discharge Current Impulse Life Minimum Insulation Resistance Maximum Capacitance Device Marking Code 100V/s 1000V/μs 8/20μs 10times 50Hz,1sec 10/1000μs 100A Test Voltage (GΩ) 1MHz (V) (V) (KA) (A) (times) DC(V) (pF) 2RP075L-8 2RP075M-8 75±20% 600 20 20 500 25 1.0 1.5 2RP075-8 2RP090L-8 2RP090M-8 90±20% 600 20 20 500 50 1.0 1.5 2RP090-8 2RP120L-8 2RP120M-8 120±20% 600 20 20 500 50 1.0 1.5 2RP120-8 2RP145L-8 2RP145M-8 145±20% 700 20 20 500 100 1.0 1.5 2RP145-8 2RP150L-8 2RP150M-8 150±20% 700 20 20 500 100 1.0 1.5 2RP150-8 2RP230L-8 2RP230M-8 230±20% 700 20 20 500 100 1.0 1.5 2RP230-8 2RP250L-8 2RP250M-8 250±20% 800 20 20 500 100 1.0 1.5 2RP250-8 2RP300L-8 2RP300M-8 300±20% 900 20 20 500 100 1.0 1.5 2RP300-8 2RP350L-8 2RP350M-8 350±20% 900 20 20 500 100 1.0 1.5 2RP350-8 2RP400L-8 2RP400M-8 400±20% 1000 20 20 500 100 1.0 1.5 2RP400-8 2RP470L-8 2RP470M-8 470±20% 1100 20 20 500 250 1.0 1.5 2RP470-8 2RP600L-8 2RP600M-8 600±20% 1300 20 20 500 250 1.0 1.5 2RP600-8 2RP800L-8 2RP800M-8 800±20% 1500 20 20 500 250 1.0 1.5 2RP800-8 Electrical Ratings Items Test Condition/Description Requirement DC Spark-over Voltage The voltage is measured with voltage ramp dv/dt=100V/s. To meet the specified value Maximum Impulse Spark-over Voltage The maximum impulse spark-over voltage is measured with voltage ramp dv/dt=1000V/ μs. Impulse Discharge Current Maximum 8/20 μs surge current that can be applied between two electrodes, 5 positive and 5 negative surges, with 3 minutes interval time. 0 10 50 90 100 Time Impulse Width 8µs 20µs Crest value Alternating Discharge Current Rated RMS value of AC current at 50Hz, 1 sec. for 10 times with interval time 3 min. Insulation Resistance The resistance of gas tube shall be measured between two electrodes. Capacitance The capacitance of gas tube shall be measured between two electrodes. Test frequency: 1MHz |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |