| Electronic Components Datasheet Search |
|
093.48 Datasheet(PDF) 13 Page - Finder Relays, Inc. |
|
|
|||||||||||||||||||||||||||||
093.48 Datasheet(HTML) 13 Page - Finder Relays, Inc. |
|
13 / 20 page ![]() B Coil specifications - 1 Pole 6 A Electromechnical Relay Coil data sensitive DC, 1 Pole Coil data AC/DC, 1 Pole Nominal voltage Coil code Operating range Rated coil consumption Power consumption UN Umin Umax I at UN P at UN V V V mA W 6 7.006 4.8 7.2 35 0.2 12 7.012 9.6 14.4 15.2 0.2 24 7.024 19.2 28.8 10.4 0.3 48 7.048 38.4 57.6 6.3 0.3 60 7.060 48 72 7 0.4 Nominal voltage Coil code Operating range Rated coil consumption Power consumption UN Umin Umax I at UN P at UN V V V mA VA/W 12 0.012 9.6 13.2 16 0.2/0.2 24 0.024 19.2 26.4 12 0.3/0.2 48 0.048 38.4 52.8 6.9 0.3/0.3 60 0.060 48 66 7 0.5/0.5 110…125 0.125 88 138 5(*) 0.6/0.6(*) 220…240 0.240 176 264 4(*) 1/0.9(*) (*) Rated coil consumption and power consumption values relate to UN = 125 and 240 V. Coil data AC, 1 Pole (indicated for max ambient temperature +70 °C) Nominal voltage Coil code Operating range Rated coil consumption Power consumption UN Umin Umax I at UN P at UN V V V mA VA/W (230…240) AC 8.240 184 264 3 0.7/0.3 Coil data, leakage current suppression types, 1 Pole Nominal voltage Coil code Operating range Rated coil consumption Power consumption UN Umin Umax I at UN P at UN V V V mA VA/W (110…125) AC/DC 3.125 94 138 8(*) 1/1(*) (230…240) AC 3.240 184 264 7(*) 1.7/0.5(*) (*) Rated coil consumption and power consumption values relate to UN = 125 and 240 V. The 38 Series interface modules (supply version 3) have built-in leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at (110…125)V AC and (230…240)V AC. This problem can occur, for example, when connecting the interface modules to PLC‚s with triac outputs or when connecting via relatively long cables. Coil specifications - 1 Pole 16 A and 2 Pole 8 A Electromechanical Relay Coil data sensitive DC, 1 Pole 16 A and 2 Pole 8 A Nominal voltage Coil code Operating range Rated coil consumption Power consumption UN Umin Umax I at UN P at UN V V V mA W 12 7.012 9.6 14.4 41 0.5 24 7.024 19.2 28.8 19.5 0.5 60 7.060 48 72 8 0.5 Coil data AC/DC, 1 Pole 16 A and 2 Pole 8 A Nominal voltage Coil code Operating range Rated coil consumption Power consumption UN Umin Umax I at UN P at UN V V V mA W 24 0.024 19.2 26.4 20 0.5/0.5 60 0.060 48 66 7.1 0.5/0.5 110…125 0.125 88 138 4.6 0.6/0.6 220…240 0.240 184 264 3.8 0.9/0.9 Coil data AC, 1 Pole 16 A and 2 Pole 8 A Nominal voltage Coil code Operating range Rated coil consumption Power consumption UN Umin Umax I at UN P at UN V V V mA VA/W 230…240 8.230 184 264 5.3 1.2/0.6 Coil specification - 1 & 2 Pole Electromagnetic Relays R 38 - DC coil operating range v ambient temperature 1 Pole and 2 Pole 1 2 3 4 1 - Max. permitted coil voltage at nominal load (DC coil). 2 - Max. permitted coil voltage at nominal load (AC/DC coils U ≤ 60 V). 3 - Max. permitted coil voltage at nominal load (AC/DC coils U > 60 V). 4 - Min pick-up voltage with coil at ambient temperature. 9 38 SERIES 38 SERIES Relay interface modules - Technical data |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |