| Electronic Components Datasheet Search |
|
LPT80 Datasheet(PDF) 2 Page - Emerson Network Power |
|
|
|||||||||||||||||||||||||||||
LPT80 Datasheet(HTML) 2 Page - Emerson Network Power |
|
2 / 3 page ![]() Embedded Power for Business-Critical Continuity Ordering Information Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30CFM forced Air Peak Load 1 Regulation 2 Ripple P/P (PARD)3 LPT81 +3.3 V (1.8 - 3.5 V) +5 V (3.3 - 5.5 V) +12 V 0.7 A 0.3 A 0 8.0 A 4.0 A 0.7 A 13 A13 A 1.0 A 15 A 15 A 1.5 A ±2% ±2% ±5% 50 mV 50 mV 120 mV LPT82 +5 V (3.3 - 5.5 V) +12 V -12 V 0.7 A 0.3 A 0 8.0 A 3.0 A 0.7 A 13 A 4.0 A 1.0 A 15 A 4.6 A 1.5 A ±2% ±5% ±5% 50 mV 120 mV 120 mV LPT83 +5 V (3.3 - 5.5 V) +15 V -15 V 0.7 A 0.3 A 0 8.0 A 2.4 A 0.7 A 13 A 3.2 A 0.7 A 15 A 3.7 A 1 A ±2% ±5% ±5% 50 mV 150 mV 150 mV 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. 4. Minimum loads are required 5. Total current of all outputs can not exceed 21 A. Rev. 05.23.08 LPT80 Series 2 of 3 Operating temperature: 0° to 50 °C ambient; derate each output at 2.5% per degree from 50° to 70°C Temperature coefficient: ±0.4% per °C Storage temperature: -40° to 85 °C Electromagnetic susceptibility: Designed to meet IEC EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational MTBF demonstrated: >550,000 hours at full load and 25 °C ambient conditions Environmental Specifications Logic Control Power failure TTL logic signal goes high 100 - 500 msec after V1 output; It goes low at least 4 msec before loss of regulation Remote inhibit Requires contact closure to inhibit outputs Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |