| Electronic Components Datasheet Search |
|
VR100B080CU-2C Datasheet(PDF) 2 Page - Murata Power Solutions Inc. |
|
|
|||||||||||||||||||||||||||||
VR100B080CU-2C Datasheet(HTML) 2 Page - Murata Power Solutions Inc. |
|
2 / 6 page ![]() DC/DC Converter Programmable, Single Output, 1.1V - 1.85Vout @ 60A DC/DC Converter Programmable, Single Output, 0.8375V - 1.600Vout @ 80A Notes: 1. Vin = 12Vdc, Ta = 25°C, Airflow = 400LFM unless otherwise noted. 2. Output Ripple Voltage is specified when measured with Intel specified capacitance at the output of the converter. 3. Transient response is specified with Intel specified capacitors at the output of the converter. 4. If remote sense is not required or used, the Sense(+) and Sense(-) pins must be connected to Vo(+) and Vo(-) respectively. 5. User will select the appropriate Load Line through the LL0 and LL1 signals. LL0 and LL1 signals are TTL compatible. The default state is a 1.25mOhm Load Line. 6. VRM_PRES and VRM_ID are connected to Vss on the VRM. 7. During operation within Thermal Derating Curve boundaries. Remote Sense Compensation Range (4) 300 mV Recommended Bulk Output Capacitance UCC 4PS560MH11 or Panasonic EEFSDOD471R 10 EA Table 3: Protection Characteristics Notes and Conditions (1) Min Typ Max Units Output Overcurrent Shutdown Latching 83 120 A Overvoltage Shutdown Above VID 90 200 mV Overtemperature Indicator Non-Latching, at hot spots Worst case junction temperature 125 °C Load Indicator VID = 1.325, 0A Load, LL1 = 1 VID = 1.325, 100A Load, LL1 = 1 1 3 V V VID = 1.325, 0A Load, LL1 = 0 VID = 1.325, 100A Load, LL1 = 0 1 3.75 V V Table 4: General Characteristics Notes and Conditions (1) Min Typ Max Units Storage Temperature Range Non-condensing -40 70 °C Operating Ambient Temperature Range (7) 065 °C Semiconductor Junction Temperature Package rated to 150°C 110 °C Material Flammability UL 94V-0 MTBF Calculated (RAC PRISM) @ 45°C 0.93 x106 Hrs Switching Frequency Per phase 300 KHz Dimensions 3.8”L x 1.18”H x 0.475”W Weight 30 g Table 5: Adaptive Voltage Positioning Notes and Conditions (1) Min Typ Max Units Voltage Droop for 100A Load (linear) LL0 = X, LL1 = 0 LL0 = X, LL1 = 1 125 91 mV Table 2: Output Characteristics Notes and Conditions (1) Min Typ Max Units Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000 www.murata-ps.com |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |