Back Button MCP73862-I/ML Datasheet HTML 14Page - Microchip Technology MCP73862-I/ML Datasheet HTML 15Page - Microchip Technology MCP73862-I/ML Datasheet HTML 16Page - Microchip Technology MCP73862-I/ML Datasheet HTML 17Page - Microchip Technology MCP73862-I/ML Datasheet HTML 18Page - Microchip Technology MCP73862-I/ML Datasheet HTML 19Page - Microchip Technology MCP73862-I/ML Datasheet HTML 20Page - Microchip Technology MCP73862-I/ML Datasheet HTML 21Page - Microchip Technology MCP73862-I/ML Datasheet HTML 22Page - Microchip Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 34 page
background image
MCP73861/2/3/4
DS21893D-page 18
© 2008 Microchip Technology Inc.
5.1.6
BATTERY VOLTAGE SENSE (VBAT3)
The MCP7386X monitors the battery voltage at the
VBAT3 pin. This input is tied directly to the positive
terminal of the battery pack.
5.1.7
BATTERY CHARGE CONTROL
OUTPUT (VBAT1, VBAT2)
The battery charge control output is the drain terminal
of an internal P-channel MOSFET. The MCP7386X
provides constant current and voltage regulation to the
battery pack by controlling this MOSFET in the linear
region. The battery charge control output should be
connected to the positive terminal of the battery pack.
5.2
Digital Circuitry
5.2.1
CHARGE STATUS OUTPUTS
(STAT1, STAT2)
Two status outputs provide information on the state of
charge. The current-limited, open-drain outputs can be
used to illuminate external LEDs. Optionally, a pull-up
resistor can be used on the output for communication
with a host microcontroller. Table 5-1 summarizes the
state of the status outputs during a charge cycle.
The flashing rate (1 Hz) is based off a timer capacitor
(CTIMER) of 0.1 µF. The rate will vary based on the
value of the timer capacitor.
During a fault condition, the STAT1 status output will be
off and the STAT2 status output will be on. To recover
from a fault condition, the input voltage must be
removed and then reapplied, or the enable input (EN)
must be de-asserted to a logic-low, then asserted to a
logic-high.
When the voltage on the THERM input is outside the
preset window, the charge cycle will not start, or will be
suspended. The charge cycle is not terminated and
recovery is automatic. The charge cycle will resume (or
start) once the THERM input is valid and all other
qualification parameters are met. During an invalid
THERM condition, the STAT1 status output will be off
and the STAT2 status output will flash.
5.2.2
VSET INPUT
The VSET input selects the regulated output voltage of
the MCP7386X. With VSET tied to VSS, the MCP73861/
3 and MCP73862/4 regulate to 4.1V and 8.2V,
respectively. With VSET tied to VDD, the MCP73861/3
and MCP73862/4 regulate to 4.2V and 8.4V,
respectively.
5.2.3
LOGIC ENABLE (EN)
The logic enable input pin (EN) can be used to
terminate a charge at any time during the charge cycle,
as well as to initiate a charge cycle or initiate a recharge
cycle.
Applying a logic-high input signal to the EN pin, or tying
it to the input source, enables the device. Applying a
logic-low input signal disables the device and
terminates a charge cycle. When disabled, the device’s
supply current is reduced to 0.17 µA, typically.
TABLE 5-1:
STATUS OUTPUTS (NOTE)
CHARGE
CYCLE STAT1
STAT1
STAT2
Qualification
Off
Off
Preconditioning
On
Off
Constant-
Current Fast
Charge
On
Off
Constant-
Voltage
On
Off
Charge
Complete
Flashing (1 Hz,
50% duty cycle)
(MCP73861/2)
Off
(All Devices)
Off
(MCP73863/4)
Fault
Off
On
THERM Invalid
Off
Flashing (1 Hz,
50% duty cycle)
Disabled –
Sleep mode
Off
Off
Input Voltage
Disconnected
Off
Off
Note:
Off state: Open-drain is high-impedance
On state: Open-drain can sink current
typically 7 mA
Flashing: Toggles between off state and
on state



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com