55 / 84 page ![]() Low-Power, Active Energy, Polyphase AFE ______________________________________________________________________________________ 55 Meter Pulse The purpose of a meter pulse is generally to advance a mechanical counter when such a device is used as a display. Meter pulses are also used during calibration since time intervals can be measured with great preci- sion. The MAXQ3181 supports one meter pulse output. This output can be configured for either active positive or active negative pulses by means of the POPOL bit in the OPMODE1 register. When triggered, the pulse goes to its active state and remains there for a period of time defined by the PLS1_WD register, and then returns to the inactive state (unless triggered again). The PLS1_WD register contains the time in ADC frame periods that the pulses remain in the active state when triggered. By default, this register contains decimal 156 (0x9C) giving, at the default frame rate, a pulse width of 50ms. Among the quantities that can be accumulated by the pulse subsystem are the arithmetic active energy (that is, the accumulated positive real energy minus the accumulated negative real energy) and the absolute active energy (that is, accumulated positive real energy plus accumulated negative real energy). Other quanti- ties include RMS voltage and current, positive and neg- ative real energy. Select the desired accumulation value in the QNSEL field of the PLSCFG1 register. Also in the pulse configuration registers you can select which phases to include in the accumulation. Set any or all the PHASEA, PHASEB, and PHASEC bits in the PLSCFG1 register to include them in the accumulation. Generating Pulses On every DSP cycle, the MAXQ3181 adds the value in the selected register (or set of registers) to the pulse accumulator. If the value in the pulse accumulator exceeds the value in the associated threshold register (THR1), then a pulse is started and the value in the threshold register is subtracted from the value in the pulse accumulator. Meter Constant A meter constant is the number of pulses that are gen- erated during a standard measurement interval; for example, a meter might specify a meter constant of 1600 pulses per kilowatt-hour. The THR1 register is used to specify the meter constant according to the fol- lowing formula: In this formula, THR is the value to be written to the threshold register, KM is the desired meter constant (in pulses per kilowatt hour), IFS and VFS are the full-scale voltage and current, respectively, and tFR is the frame period in units of hours, as in the previous calculation. As an example, assume once again a full-scale voltage value of 558.1V = 0.5581kV, a full-scale current value of 102.4A, a desired meter constant of 1600 pulses per kilowatt hour, and a default frame time of 320μs (88.9 x 10-9 hours). The threshold register value can be calcu- lated as: 65,536/(1600 x 102.4 x 0.5581 x 88.9 x 10-9) = 8,063,071 = 0x7B085F Increasing the value of the threshold register reduces the meter constant (that is, there are fewer pulses per kilowatt-hour); reducing the threshold register increases the meter constant (that is, there are more pulses per kilowatt-hour.) Interrupts The MAXQ3181 contains an interrupt subsystem to relieve the host processor of the burden of constantly polling the device for status. Instead, under certain cir- cumstances, the MAXQ3181 can activate an external pin to alert the host processor that some condition requiring host attention has occurred. Interrupts are managed globally by the IRQ_MASK and IRQ_FLAG registers. In general, when a bit becomes set in the IRQ_FLAG register, an interrupt is generated if the corresponding bit is set in the IRQ_MASK register. Interrupts can be configured for the following conditions: PWRF: This flag indicates the VDVDD to the MAXQ3181 has fallen below its nominal operating threshold (about 2.85V). This can be taken as an indication that power failure is imminent and that the host processor should begin taking steps to ensure an orderly shutdown. CHSCH: This flag indicates that the CHKSUM regis- ter changed its value. EOVF: Energy overflow. This flag indicates that one or more energy accumulators (X.EAPOS, X.EANEG, etc.) have overflowed. In a traditional meter, the host processor would poll the MAXQ3181 to determine which of the energy accumulators have overflowed and adjust its internal accounting registers accordingly. OC: The RMS current value on one or more of the phases over the most recent DSP cycle has exceed- ed the value set in the OCLVL register. THR KI V t MFS FS FR = ×× × 216 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |