9 / 14 page ![]() Product Specifications RFS Series: 20W / 6.0A DC/DC Converters Oct 2001 36-75V Input 1.5V, 1.8V, 2.5V, 3.3V and 5.0V Outputs 18-Oct-01 Rev 1.0 Page 9 of 14 www.power-one.com Typical Application This series of converters does not require any external components for proper operation. However, if the distribution of the input voltage to the converter contains significant inductance, a capacitor across the input terminals may be required to stabilize the input voltage. A minimum of 1µF, quality electrolytic / ceramic capacitor is recommended for this purpose. For output decoupling it is recommend connecting a 1µF ceramic capacitor directly across the output pins of the converter. Shutdown Feature The remote control pin functions as a normal soft shutdown. It is referenced to the –Vin pin. With positive logic, when the remote control pin is pulled low, the output is turned off and the unit goes into a very low input power mode. An open collector switch is recommended to control the voltage between the remote control pin and the -Vin pin of the converter. The remote control pin is pulled up internally, so no external voltage source is required. The user should avoid connecting a resistor between the remote control pin and the +Vin pin. The user must take care to ensure that the pin reference for the control is connected close to the - Vin pin. The control signal must not be referenced ahead of EMI filtering, or remotely from the unit. If the remote control pin is not used, it can be left floating. Thermal Considerations The converter is designed for natural or forced convection cooling. The output power of the converter is limited by the maximum case temperature (Tc). To ensure reliable long term operation of the converters, and to comply with safety agency requirements, Power-One limits maximum allowable case temperature (Tc) to 100°C (see Mechanical Drawings). Output Current Limiting When the output is overloaded above the maximum output current rating, the voltage will start to reduce to maintain the output power to a safe level. In a condition of high overload or short-circuit where the output voltage is pulled below approximately 30% of Vo.Nom, the unit will enter a ‘Hiccup’ mode of operation. Under this condition the unit will attempt to restart, approximately every 25ms until the overload has cleared. Parallel Operation Paralleling of two converters is not possible. Output Voltage Trim The trim feature allows the user to adjust the output voltage from the nominal. Output voltage can be adjusted by an external resistor. To increase Vo a resistor should be connected between pins 2 and 3. To decrease Vo a resistor should be connected between pins 1 and 3. To increase Vo: Rext = (A – (D x Vout)) / ( Vout – Vout.Nom) To reduce Vo: Rext = ((B x Vout) - C) / ( Vout.Nom - Vout) Where Vout is the desired output voltage Model A B C D RFS06ZA 1945 1470 1944 470 RFS06ZB 2590 1730 2560 750 RFS06ZD 5010 2516 5010 1500 RFS06ZE 7010 3161 7010 1500 RFS04ZG 11260 4532 11240 1500 Note: When the output voltage is trimmed up, the output power from the converter must not exceed its maximum rating. This is determined by measuring the voltage on the output pins, and multiplying it by the output current. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |