4 / 24 page

11-218
RF2945
Rev A10 000919
11
Parameter
Specification
Unit
Condition
Min.
Typ.
Max.
Power Down Control
Logical Controls “ON”
2.0
V
Voltage supplied to the input
Logical Controls “OFF”
1.0
V
Voltage supplied to the input
Control Input Impedance
25k
Ω
Turn On Time
1
ms
Turn on/off times are dependent upon
Turn Off Time
1
ms
PLL loop parameters
RX to TX and TX to RX Time
100
µs
Power Supply
Voltage
3.6
V
Specifications
2.7
5.0
V
Operating limits
Temperature range -40°C to +85°C
2.4
V
Operating limits
Temperature range +10°C to +40°C
Current Consumption
17
22
27.4
mA
TX ENABL, LVLADJ= 3.6V, RX ENABL=0V
4.8
6.1
7.2
mA
TX ENABL= 3.6V, LVLADJ, RX ENABL= 0V
4.4
6.1
6.8
mA
TX ENABL= 0V, RX ENABL= 3.6V
1
µA
TX ENABL, LVLADJ, RX ENABL= 0V
3.6
mA
PLL Only Mode, TX ENABL,
RX ENABL= 3.6V, LVLADJ= 0V