21 / 29 page ![]() ALTAIR04-900 Application information Doc ID 18211 Rev 2 21/29 5.10 Layout recommendations A proper printed circuit board layout is essential for correct operation of any switch-mode converter and this is true for the ALTAIR04-900 as well. Careful component placing, correct traces routing, appropriate traces widths and compliance with isolation distances are the major issues. In particular: ● The compensation network should be connected as close as possible to the COMP pin, maintaining the trace for the GND as short as possible ● Signal Ground should be routed separately from power ground, as well from the sense resistor trace. Figure 19. Suggested routing for converter AC IN OUT GND COMP SOURCE DRAIN VDD IREF GND FB/ZCD ALTAIR04-900 AC IN |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|