| Electronic Components Datasheet Search |
|
300-R010-45G Datasheet(PDF) 16 Page - Magnetrol International, Inc. |
|
|
|||||||||||||||||||||||||||||
300-R010-45G Datasheet(HTML) 16 Page - Magnetrol International, Inc. |
|
16 / 36 page ![]() SOFTWARE CONFIGURATION cont. 18" (457 mm) Range Span NO YES Figure 9 Figure 10 16 Maximum span should never be great enough to allow level measurement inside the nozzle, where the ultrasonic transducer is mounted. SYSTEM CONFIGURATION MENU—LEVEL ONLY cont. System Configuration Menu (Level Only) cont. Display Keystroke Comment and/or Additional Keystrokes Range Setting Press ENT or Press ENT to change the range setting. If setting is correct press xxxx units to continue to Span Settings. Refer to Figure 9. NOTE: It is recommended to use Manual Set (as opposed to Auto Set) when changing the range or span settings. Press ENT to manually set the range setting. An will appear in the bottom line Manual Set Press ENT or of the display. This allows you to change the range value. Measure the xxxx units distance from the face of the transducer to the maximum distance to be measured. Enter value and press ENT. If Auto Set is preferred press . The liquid surface must be at the maximum distance to be measured. Auto Set (If chosen) Press ENT or Check to see that the distance being displayed is correct. When you press the xxxx units ENT key, that distance will be set as your range and the program will continue on to the next selection. To continue without making changes press . NOTE: The span value is automatically set ONLY when the entered range value has decreased from its previous value. Span Setting Value shown will be 18 inches less than the range setting. This is the maximum xxxx units Press ENT or span value available. If you want to reduce the span, press ENT. Refer to Figures 9 and 10. If the present setting is correct press to continue to Previous Menu. Manual Set Press ENT to manually set the span setting. Measure the distance from the xxxx units Press ENT or maximum range that was set to the highest point to be measured. Enter value and press ENT. If Auto Set is preferred press . The liquid surface must be at the highest level to be measured. Auto Set (If chosen) Press ENT or Check to see that the level being displayed is correct. When you press the ENT xxxx units key, that measurement will be set as your span and the program will continue on to the next selection. To continue without changes press . Previous Menu Press ENT Pressing the ENT key will set all values and return to System Config. Press DEL ENT to select to return to the run mode. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |