Back Button ADIS16480/PCBZ Datasheet HTML 29Page - Analog Devices ADIS16480/PCBZ Datasheet HTML 30Page - Analog Devices ADIS16480/PCBZ Datasheet HTML 31Page - Analog Devices ADIS16480/PCBZ Datasheet HTML 32Page - Analog Devices ADIS16480/PCBZ Datasheet HTML 33Page - Analog Devices ADIS16480/PCBZ Datasheet HTML 34Page - Analog Devices ADIS16480/PCBZ Datasheet HTML 35Page - Analog Devices ADIS16480/PCBZ Datasheet HTML 36Page - Analog Devices ADIS16480/PCBZ Datasheet HTML 37Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 33 / 40 page
background image
Data Sheet
ADIS16480
Rev. 0 | Page 33 of 40
BAROMETERS
The BR_BIAS_HIGH register (see Table 130) and
BR_BIAS_LOW register (Table 131) provide an offset
control function and use the same format as the output
registers, BAROM_OUT and BAROM_LOW.
Table 130. BR_BIAS_HIGH (Page 2, Base Address = 0x42)
Bits
Description (Default = 0x0000)
[15:0]
Barometric pressure bias correction factor, high word
Twos complement, ±1.3 bar measurement range,
0 bar = 0x0000, 1 LSB = 40 µbar
Table 131. BR_BIAS_LOW (Page 2, Base Address = 0x40)
Bits
Description (Default = 0x0000)
[15:0]
Barometric pressure bias correction factor, low word
Twos complement, ±1.3 bar measurement range,
0 bar = 0x0000, 1 LSB = 40 µbar ÷ 216 = ~0.00061 µbar
RESTORING FACTORY CALIBRATION
Turn to Page 3 (DIN = 0x8003) and set GLOB_CMD[6]
= 1 (DIN = 0x8240, DIN = 0x8300) to execute the factory
calibration restore function. This function resets each user
calibration register to zero, resets all sensor data to 0, and
automatically updates the flash memory within 72 ms. See
Table 146 for more information on GLOB_CMD.
POINT OF PERCUSSION ALIGNMENT
CONFIG[6] offers a point of percussion alignment function
that maps the accelerometer sensors to the corner of the package
identified in Figure 25. To activate this feature, turn to Page 3
(DIN = 0x8003), then set CONFIG[6] = 1 (DIN = 0x8A40,
DIN = 0x8B00). See Table 106 for more information on the
CONFIG register.
PIN 1
PIN 23
POINT OF PERCUSSION
ALIGNMENT REFERENCE POINT.
SEE CONFIG[6].
Figure 25. Point of Percussion Reference Point



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com