| Electronic Components Datasheet Search |
|
SLAS191A Datasheet(PDF) 55 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
SLAS191A Datasheet(HTML) 55 Page - Texas Instruments |
|
55 / 86 page ![]() 2–19 g The g command starts/restarts the user application that is loaded into RAM. The system retrieves the start vector of a user’s application from memory location (3FEh on the 320 STK/EVK, 5FEh on the 330 EVK) if a new program is loaded, or after executing a PUC command or a user reset. Otherwise, the program execution continues with the actual PC (R0). Return to the Monitor occurs after pressing any key on the keyboard. The g command functions as stated if the user application is not running in an interrupt routine (GIE=0 if interrupt nesting is not allowed), and the user application has not disabled the GIE bit. Enter g to start the user application >init MSP–STK430A320 >@0300 31 40 00 04 B2 40 80 5A 20 01 07 43 17 53 FE 3F @03FE 00 03 q >downloaded _PC_ _SP_ _SR_ reg 0000 : 0300 03de 0008 0000 f48c 1d14 0069 000e reg 0008 : 1a28 4032 0000 ffd0 4040 6803 e2c2 07a0 >go.._ Figure 2–20. Starting the Application Command |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|