  B3786 Datasheet HTML 1Page - EPCOS B3786 Datasheet HTML 2Page - EPCOS B3786 Datasheet HTML 3Page - EPCOS B3786 Datasheet HTML 4Page - EPCOS B3786 Datasheet HTML 5Page - EPCOS B3786 Datasheet HTML 6Page - EPCOS B3786 Datasheet HTML 7Page - EPCOS B3786 Datasheet HTML 8Page - EPCOS B3786 Datasheet HTML 9Page - EPCOS Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 10 page
background image
3
August 10, 2010
B3786
313.85 / 315.00 MHz
SAW Components
SAW RF filter
Data sheet
Please read
cautions and warnings and
important notes at the end of this document.
Characteristics
Temperature range for specification:
T
= –45 ˚C to +95 ˚C
Terminating source impedance:
ZS =50 Ω and matching network tbd
Terminating load impedance:
ZL =50 Ω and matching network tbd
min.
typ.
@ 25 ˚C
max.
Pass band 1
Center frequency
fC1
313.85
MHz
Minimum insertion attenuation
α
min1
incl. loss in matching elements
2.6
3.2
dB
excl. loss in matching elements
2.1
2.6
dB
Pass band (relative to
α
min1)
313.70 ...
314.00 MHz
1.0
2.0
dB
313.67 ...
314.03 MHz
1.4
3.0
dB
Pass band 2
Center frequency
fC2
315.00
MHz
Minimum insertion attenuation
α
min2
incl. loss in matching elements
2.6
3.2
dB
excl. loss in matching elements
2.1
2.6
dB
Pass band (relative to
α
min2)
314.85 ...
315.15 MHz
1.0
2.0
dB
314.82 ...
315.18 MHz
1.4
3.0
dB
Relative attenuation (relative to
α
min1)
α
rel
10.00 ...
260.00 MHz
50
55
dB
260.00 ...
308.00 MHz
42
47
dB
308.00 ...
312.40 MHz
24
30
dB
312.40 ...
313.20 MHz
15
20
dB
314.30 ...
314.60 MHz
6
dB
315.70 ...
316.50 MHz
15
20
dB
316.50 ...
325.00 MHz
22
26
dB
325.00 ...
335.00 MHz
38
43
dB
335.00 ...
380.00 MHz
42
47
dB
380.00 ...
600.00 MHz
50
55
dB
600.00 ... 1000.00 MHz
56
60
dB
1000.00 ... 2000.00 MHz
50
55
dB
Impedance for pass band matching1)
1)
Impedance for passband matching bases on an ideal, perfect matching of the SAW filter to source- and to load
impedance (here 50 Ohm). After removal of the SAW filter the input impedance of the input and output match-
ing network is calculated. The conjugate complex value of these characteristic impedances are the input and
output impedances for flat passband. For more details we refer to EPCOS application note #4.
Input:
ZIN
=RIN
|| CIN
425 || 4.3
Ω || pF
Output: ZOUT =ROUT || COUT
425 || 4.3
Ω || pF



Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com