2 / 12 page ![]() –2– REV. 0 ADM1021–SPECIFICATIONS (T A = TMIN to TMAX, VDD = 3.0 V to 3.6 V, unless otherwise noted) Parameter Min Typ Max Units Test Conditions/Comments POWER SUPPLY AND ADC Temperature Resolution 1 °C Guaranteed No Missed Codes Temperature Error, Local Sensor ±1 °C –3 +3 °C Temperature Error, Remote Sensor –3 +3 °CT A = +60 °C to +100°C –5 +5 °C Supply Voltage Range 3 3.6 V Note 1 Undervoltage Lockout Threshold 2.5 2.7 2.95 V VDD Input, Disables ADC, Rising Edge Undervoltage Lockout Hysteresis 25 mV Power-On Reset Threshold 0.9 1.7 2.2 V VDD, Falling Edge 2 POR Threshold Hysteresis 50 mV Standby Supply Current 3 10 µAV DD = 3.3 V, No SMBus Activity 4 µA SCLK at 10 kHz Average Operating Supply Current 70 90 µA 0.25 Conversions/Sec Rate Auto-Convert Mode, Averaged Over 4 Seconds 160 200 µA 2 Conversions/Sec Rate Conversion Time 65 115 170 ms From Stop Bit to Conversion Complete (Both Channels) Remote Sensor Source Current D+ Forced to D– + 0.65 V 60 90 130 µA High Level 3.5 5.5 8 µA Low Level D-Source Voltage 0.7 V Address Pin Bias Current (ADD0, ADD1) 50 µA Momentary at Power-On Reset SMBUS INTERFACE Logic Input High Voltage, VIH 2.2 V VDD = 3 V to 5.5 V STBY, SCLK, SDATA Logic Input Low Voltage, VIL 0.8 V VDD = 3 V to 5.5 V STBY, SCLK, SDATA SMBus Output Low Sink Current 6 mA SDATA Forced to 0.6 V ALERT Output Low Sink Current 1 mA ALERT Forced to 0.4 V Logic Input Current, IIH, IIL –1 +1 µA SMBus Input Capacitance, SCLK, SDATA 5 pF SMBus Clock Frequency 0 100 kHz SMBus Clock Low Time, tLOW 4.7 µst LOW Between 10% Points SMBus Clock High Time, tHIGH 4 µst HIGH Between 90% Points SMBus Start Condition Setup Time, tSU:STA 4.7 µs SMBus Repeat Start Condition 250 ns Between 90% and 90% Points Setup Time, tSU:STA SMBus Start Condition Hold Time, tHD:STA 4 µs Time from 10% of SDATA to 90% of SCLK SMBus Stop Condition Setup Time, tSU:STO 4 µs Time from 90% of SCLK to 10% of SDATA SMBus Data Valid to SCLK 250 ns Time from 10% or 90% of Rising Edge Time, tSU:DAT SDATA to 10% of SCLK SMBus Data Hold Time, tHD:DAT 0 µs SMBus Bus Free Time, tBUF 4.7 µs Between Start/Stop Condition SCLK Falling Edge to SDATA 1 µs Master Clocking in Data Valid Time, tVD,DAT NOTES 1Operation at V DD = +5 V guaranteed by design, not production tested. 2Guaranteed by design, not production tested. Specifications subject to change without notice. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |