14 / 53 page ![]() 14 3596O–DFLASH–1/2013 AT45DB081D 9.1 Sector Protection Register The nonvolatile Sector Protection Register specifies which sectors are to be protected or unpro- tected with either the software or hardware controlled protection methods. The Sector Protection Register contains 16-bytes of data, of which byte locations 0 through 15 contain values that specify whether sectors 0 through 15 will be protected or unprotected. The Sector Protection Register is user modifiable and must first be erased before it can be reprogrammed. Table 9-3 illustrates the format of the Sector Protection Register.: Note: 1. The default value for bytes 0 through 15 when shipped from Adesto is 00H x = don’t care 9.1.1 Erase Sector Protection Register Command In order to modify and change the values of the Sector Protection Register, it must first be erased using the Erase Sector Protection Register command. To erase the Sector Protection Register, the CS pin must first be asserted as it would be with any other command. Once the CS pin has been asserted, the appropriate 4-byte opcode sequence must be clocked into the device via the SI pin. The 4-byte opcode sequence must start with 3DH and be followed by 2AH, 7FH, and CFH. After the last bit of the opcode sequence has been clocked in, the CS pin must be deasserted to initiate the internally self-timed erase cycle. The erasing of the Sector Protection Register should take place in a time of tPE, during which time the Status Register will indicate that the device is busy. If the device is powered- down before the completion of the erase cycle, then the contents of the Sector Protection Regis- ter cannot be guaranteed. The Sector Protection Register can be erased with the sector protection enabled or disabled. Since the erased state (FFH) of each byte in the Sector Protection Register is used to indicate that a sector is specified for protection, leaving the sector protection enabled during the erasing of the register allows the protection scheme to be more effective in the prevention of accidental programming or erasing of the device. If for some reason an erroneous program or erase com- mand is sent to the device immediately after erasing the Sector Protection Register and before the register can be reprogrammed, then the erroneous program or erase command will not be processed because all sectors would be protected. Table 9-2. Sector Protection Register Sector Number 0 (0a, 0b) 1 to 15 Protected See Table 9-3 FFH Unprotected 00H Table 9-3. Sector 0 (0a, 0b) 0a 0b Bit 3, 2 Data Value (Page 0-7) (Page 8-255) Bit 7, 6 Bit 5, 4 Bit 1, 0 Sectors 0a, 0b Unprotected 00 00 xx xx 0xH Protect Sector 0a 11 00 xx xx CxH Protect Sector 0b (Page 8-255) 00 11 xx xx 3xH Protect Sectors 0a (Page 0-7), 0b (Page 8-255)(1) 11 11 xx xx FxH |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |