| Electronic Components Datasheet Search |
|
TMP17 Datasheet(PDF) 4 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
TMP17 Datasheet(HTML) 4 Page - Analog Devices |
|
4 / 8 page ![]() TMP17 REV. 0 –4– THEORY OF OPERATION The TMP17 uses a fundamental property of silicon transistors to realize its temperature proportional output. If two identical transistors are operated at a constant ratio of collector current densities, r, then the difference in base-emitter voltages will be (kT/q)(ln r). Since both k, Boltzmann’s constant, and q, the charge of an electron, are constant, the resulting voltage is directly Proportional To Absolute Temperature (PTAT). In the TMP17 this difference voltage is converted to a PTAT current by low temperature coefficient thin film resistors. This PTAT current is then used to force the total output current to be proportional to degrees Kelvin. The result is a current source with an output equal to a scale factor times the temperature (K) of the sensor. A typical V-I plot of the circuit at 125 °C and the temperature extremes is shown in Figure 6. Factory trimming of the scale factor to 1 µA/K is accomplished at the wafer level by adjusting the TMP17’s temperature reading so it corresponds to the actual temperature. During laser trimming the IC is at a temperature within a few degrees of 25 °C and is powered by a 5 V supply. The device is then packaged and automatically temperature tested to specification. FACTORS AFFECTING TMP17 SYSTEM PRECISION The accuracy limits given on the Specifications page for the TMP17 make it easy to apply in a variety of diverse applica- tions. To calculate a total error budget in a given system it is important to correctly interpret the accuracy specifications, non- linearity errors, the response of the circuit to supply voltage variations and the effect of the surrounding thermal environ- ment. As with other electronic designs external component selection will have a major effect on accuracy. CALIBRATION ERROR, ABSOLUTE ACCURACY AND NONLINEARITY SPECIFICATIONS Two primary limits of error are given for the TMP17 such that the correct grade for any given application can easily be chosen for the overall level of accuracy required. They are the calibra- tion accuracy at 25 °C, and the error over temperature from 40 °C to 105°C. These specifications correspond to the actual error the user would see if the current output of a TMP17 were converted to a voltage with a precision resistor. Note that the maximum error at room temperature or over an extended range, including the boiling point of water, can be directly read from the specifications table. The error limits are a combination of initial error, scale factor variation and non- linearity deviation from the ideal 1 µA/K output. Figure 2 graphically depicts the guaranteed limits of accuracy for a TMP17GS. The TMP17 has a highly linear output in comparison to older technology sensors (i.e., thermistors, RTDs and thermo- couples), thus a nonlinearity error specification is separated from the absolute accuracy given over temperature. As a maximum deviation from a best-fit straight line this specification represents the only error that cannot be trimmed out. Figure 8 is a plot of typical TMP17 nonlinearity over the full rated temperature range. 0.2 0.1 0 0.1 0.2 TEMPERATURE – C 40 105 25 0 25 70 TYPICAL NONLINEARITY Figure 8. Nonlinearity Error (TMP17) TRIMMING FOR HIGHER ACCURACY Calibration error at 25 °C can be removed with a single temperature trim. Figure 9 shows how to adjust the TMP17’s scale factor in the basic voltage output circuit. +V TMP17 R 100 Ω 950 Ω VOUT = 1mV/K Figure 9. Basic Voltage Output (Single Temperature Trim) To trim the circuit the temperature must be measured by a reference sensor and the value of R should be adjusted so the output (V OUT) corresponds to 1 mV/K. Note that the trim procedure should be implemented as close as possible to the temperature highest accuracy is desired for. In most applications if a single temperature trim is desired it can be implemented where the TMP17 current-to-output voltage conversion takes place (e.g., output resistor, offset to an op amp). Figure 10 illustrates the effect on total error when using this technique. AFTER SINGLE TEMPERATURE CALIBRATION ACCURACY WITHOUT TRIM 1.0 0.5 25 105 25 0 0.5 1.0 TEMPERATURE – C 40 Figure 10. Effect of Scale Factor Trim on Accuracy |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |