| Electronic Components Datasheet Search |
|
VNH2SP30TR-E Datasheet(PDF) 21 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
VNH2SP30TR-E Datasheet(HTML) 21 Page - STMicroelectronics |
|
21 / 33 page ![]() VNH2SP30-E Application information 21/33 When a fault condition is detected, the user can know which power element is in fault by monitoring the INA, INB, DIAGA/ENA and DIAGB/ENB pins. In any case, when a fault is detected, the faulty leg of the bridge is latched off. To turn on the respective output (OUTX) again, the input signal must rise from low to high level. Note: In case of the fault condition is not removed, the procedure for unlatching and sending the device in Stby mode is: - Clear the fault in the device (toggle : INA if ENA=0 or INB if ENB=0) - Pull low all inputs, PWM and Diag/EN pins within tDEL. If the Diag/En pins are already low, PWM=0, the fault can be cleared simply toggling the input. The device will enter in stby mode as soon as the fault is cleared. 3.1 Reverse battery protection Three possible solutions can be considered: 1. a Schottky diode D connected to VCC pin 2. an N-channel MOSFET connected to the GND pin (see Figure 32: Typical application circuit for DC to 20 kHz PWM operation short circuit protection on page 20) 3. a P-channel MOSFET connected to the VCC pin The device sustains no more than -30A in reverse battery conditions because of the two body diodes of the power MOSFETs. Additionally, in reverse battery condition the I/Os of VNH2SP30-E are pulled down to the VCC line (approximately -1.5V). A series resistor must Figure 33. Behavior in fault condition (How a fault can be cleared) IN A IN B DIAG A EN A DIAG B EN B Iout A out B FAULT A (Internal Signal) FAULT B (Internal Signal) Normal Operation OUT B shorted to V CC t DEL Fault Cleared Stby (*) Normal Operation OUT B shorted to GND t DEL Fault Cleared Normal Operation Device Latched Device Latched Device Unlatched IN A IN B DIAG A EN A DIAG B EN B Iout A out B FAULT A (Internal Signal) FAULT B (Internal Signal) Normal Operation OUT B shorted to V CC t DEL Fault Cleared Stby (*) Normal Operation OUT B shorted to GND t DEL Fault Cleared Normal Operation Device Latched Device Latched Device Unlatched |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |