| Electronic Components Datasheet Search |
|
HPA01054DAPR Datasheet(PDF) 13 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
HPA01054DAPR Datasheet(HTML) 13 Page - Texas Instruments |
|
13 / 29 page ![]() DETAILED DESCRIPTION SETTING FOR THE CONSTANT SINK CURRENT VALUE R ( )=41 W IREF ´ V (V) IREF I (mA) OLC (1) GRAYSCALE (GS) CONTROL FUNCTION TLC5947 www.ti.com ................................................................................................................................................. SBVS114A – JULY 2008 – REVISED SEPTEMBER 2008 The constant current value for all channels is set by an external resistor (RIREF) placed between IREF and GND. The resistor (RIREF) value is calculated by Equation 1. Where: VIREF = the internal reference voltage on the IREF pin (typically 1.20 V). IOLC must be set in the range of 2 mA to 30 mA. The constant sink current characteristic for the external resistor value is shown in Figure 10. Table 1 describes the constant current output versus external resistor value. Table 1. Constant-Current Output versus External Resistor Value IOLC (mA, Typical) RIREF (Ω) 30 1640 25 1968 20 2460 15 3280 10 4920 5 9840 2 24600 Each constant current sink output OUT0–OUT23 (OUTn) turns on (starts to sink constant current) at the fifth rising edge of the grayscale internal oscillator clock after the BLANK signal transitions from high to low if the grayscale data latched into the grayscale data latch are not zero. After turn-on, the number of rising edges of the internal oscillator is counted by the 12-bit grayscale counter. Each OUTn output is turned off once its corresponding grayscale data values equal the grayscale counter or the counter reaches 4096d (FFFh). The PWM control operation is repeated as long as BLANK is low. OUTn is not turned on when BLANK is high. The timing is shown in Figure 18. All outputs are turned off at the XLAT rising edge. After that, each output is controlled again from the first clock of the internal oscillator for the next display period, based on the latest grayscale data. When the IC is powered on, the data in the grayscale data shift register and latch are not set to default values. Therefore, grayscale data must be written to the GS latch before turning on the constant current output. BLANK should be at a high level when powered on to keep the outputs off until valid grayscale data are written to the latch. This avoids the LED being randomly illuminated immediately after power-up. If having the outputs turn on at power-up is not a problem for the application, then BLANK does not need to be held high. The grayscale functions can be controlled directly by grayscale data writing, even though BLANK is connected to GND. Copyright © 2008, Texas Instruments Incorporated Submit Documentation Feedback 13 Product Folder Link(s): TLC5947 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |