9 / 11 page ![]() MP2492 – 2A, 55V, 100kHz WITH PROGRAMMABLE OUTPUT CURRENT LIMIT MP2492 Rev. 1.0 www.MonolithicPower.com 9 12/20/2010 MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited. © 2010 MPS. All Rights Reserved. Output Current Sensing The output current can be sensed through the DC resistance (DCR) of the inductor, as shown in Figure 3a. For more accurate sensing, use a more accurate sense resistor. In Figure 3a, the output current limit is set as: O U T 1 0 0 m V R b I D C R 2 R a R b =× + Where DCR is the DC resistance of the inductor winding. In Figure 3a, it is desirable to keep S R a R b L 1 C R a R b D C R × ×= + For more accurate sensing, use a more accurate sense resistor. In Figure 3b, the output current limit is set as: O U T S E N S E 1 0 0 m V I R = Figure 3—Current Sensing Methods |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|