| Electronic Components Datasheet Search |
|
PIC10LF322T-EMCSQTP Datasheet(PDF) 147 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PIC10LF322T-EMCSQTP Datasheet(HTML) 147 Page - Microchip Technology |
|
147 / 210 page ![]() 2011 Microchip Technology Inc. Preliminary DS41585A-page 147 PIC10(L)F320/322 21.11 Configuring the CWG The following steps illustrate how to properly configure the CWG to ensure a synchronous start: 1. Ensure that the TRIS control bits corresponding to CWGxA and CWGxB are set so that both are configured as inputs. 2. Clear the GxEN bit, if not already cleared. 3. Set desired dead-band times with the CWGxDBR and CWGxDBF registers. 4. Setup the following controls in CWGxCON2 auto-shutdown register: • Select desired shutdown source. • Select both output overrides to the desired levels (this is necessary even if not using auto-shutdown because start-up will be from a shutdown state). • Set the GxASE bit and clear the GxARSEN bit. 5. Select the desired input source using the CWGxCON1 register. 6. Configure the following controls in CWGxCON0 register: • Select desired clock source. • Select the desired output polarities. • Set the output enables for the outputs to be used. 7. Set the GxEN bit. 8. Clear TRIS control bits corresponding to CWGxA and CWGxB to be used to configure those pins as outputs. 9. If auto-restart is to be used, set the GxARSEN bit and the GxASE bit will be cleared automati- cally. Otherwise, clear the GxASE bit to start the CWG. 21.11.1 PIN OVERRIDE LEVELS The levels driven to the output pins, while the shutdown input is true, are controlled by the GxASDLA and GxASDLB bits of the CWGxCON2 register (Register 21-3). GxASDLA controls the CWG1A override level and GxASDLB controls the CWG1B override level. The control bit logic level corresponds to the output logic drive level while in the shutdown state. The polarity control does not apply to the override level. 21.11.2 AUTO-SHUTDOWN RESTART After an auto-shutdown event has occurred, there are two ways to have resume operation: • Software controlled • Auto-restart The restart method is selected with the GxARSEN bit of the CWGxCON2 register. Waveforms of software controlled and automatic restarts are shown in Figure 21-5 and Figure 21-6. 21.11.2.1 Software controlled restart When the GxARSEN bit of the CWGxCON2 register is cleared, the CWG must be restarted after an auto-shut- down event by software. The CWG will resume operation on the first rising edge event after the GxASE bit is cleared. Clearing the shut- down state requires all selected shutdown inputs to be low, otherwise the GxASE bit will remain set. 21.11.2.2 Auto-Restart When the GxARSEN bit of the CWGxCON2 register is set, the CWG will restart from the auto-shutdown state automatically. After the shutdown event clears, the GxASE bit will clear automatically and the CWG will resume operation on the first rising edge event. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |