| Electronic Components Datasheet Search |
|
29C040 Datasheet(PDF) 2 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
29C040 Datasheet(HTML) 2 Page - ATMEL Corporation |
|
2 / 11 page ![]() (continued) To allow for simple in-system reprogrammability, the AT29C040A does not require high input voltages for pro- gramming. Five-volt-only commands determine the opera- tion of the device. Reading data out of the device is similar t o rea ding from an EPROM. Reprogramming the AT29C040A is performed on a sector basis; 256-bytes of data are loaded into the device and then simultaneously programmed. Description (Continued) Device Operation READ: The AT29C040A is accessed like an EPROM. When CE and OE are low and WE is high, the data stored at the memory location determined by the address pins is asserted on the outputs. The outputs are put in the high impedance state whenever CE or OE is high. This dual- line control gives designers flexibility in preventing bus contention. BYTE LOAD: Byte loads are used to enter the 256- bytes of a sector to be programmed or the software codes for data protection. A byte load is performed by applying a low pulse on the WE or CE input with CE or WE low (re- spectively) and OE high. The address is latched on the falling edge of CE or WE, whichever occurs last. The data is latched by the first rising edge of CE or WE. PROGRAM: The device is reprogrammed on a sector basis. If a byte of data within a sector is to be changed, data for the entire sector must be loaded into the device. Any byte that is not loaded during the programming of its sector will be erased to read FFH. Once the bytes of a sector are loaded into the device, they are simultaneously programmed during the internal programming period. Af- ter the first data byte has been loaded into the device, suc- cessive bytes are entered in the same manner. Each new byte to be programmed must have its high to low transition on WE (or CE) within 150 µs of the low to high transition of WE (or CE) of the preceding byte. If a high to low transition is not detected within 150 µs of the last low to high transi- tion, the load period will end and the internal programming period will start. A8 to A18 specify the sector address. The sector address must be valid during each high to low tran- Block Diagram During a reprogram cycle, the address locations and 256- bytes of data are internally latched, freeing the address and data bus for other operations. Following the initiation of a program cycle, the device will automatically erase the sector and then program the latched data using an internal control timer. The end of a program cycle can be detected by DATA polling of I/O7. Once the end of a program cycle has been detected, a new access for a read or program can begin. sition of WE (or CE). A0 to A7 specify the byte address within the sector. The bytes may be loaded in any order; sequential loading is not required. Once a programming operation has been initiated, and for the duration of tWC, a read operation will effectively be a polling operation. SOFTWARE DATA PROTECTION: A software control- led data protection feature is available on the AT29C040A. Once the software protection is enabled a software algo- rithm must be issued to the device before a program may be performed. The software protection feature may be en- abled or disabled by the user; when shipped from Atmel, the software data protection feature is disabled. To enable the software data protection, a series of three program commands to specific addresses with specific data must be performed. After the software data protection is en- abled the same three program commands must begin each program cycle in order for the programs to occur. All software program commands must obey the sector pro- gram timing specifications. The SDP feature protects all sectors, not just a single sector. Once set, the software data protection feature remains active unless its disable command is issued. Power transitions will not reset the software data protection feature, however the software feature will guard against inadvertent program cycles dur- ing power transitions. After setting SDP, any attempt to write to the device with- out the three-byte command sequence will start the inter- nal write timers. No data will be written to the device; how- ever, for the duration of tWC, a read operation will effec- tively be a polling operation. 2 AT29C040A |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |