background image
Model Selection Guide
Mechanical Notes:
• All dimensions are typical
in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Notes:
1. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor be placed from
the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units.
For noise sensitive applications, the use of 4.7 µF capacitors will reduce the output ripple. The maximum
rms value of the output ripple is 10 mV.
2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
3. The maximum sink current at the on/off pin (pin 4) during a logic low is 100 µA. The maximum allowable
leakage current of a switch connected to the on/off pin (Pin 4) at logic high (2.5V to 100V) is 5 µA. If the on/
off pin (Pin 4) is left open, the unit operates. If it is grounded, the unit will shut off.
4. Operation at no-load will not damage these units. However, they may not meet all specifications.
5. Dual output units may be connected to provide a 24 VDC or 30 VDC output. To do this, connect the load
across the positive (+Vout) and negative (-Vout) outputs and float the output common.
6. The converter should be connected to a low ac-impedance source. An input source with a highly inductive
impedance may affect the stability of the converter. In applications where the converter output loading is
high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to
insure start-up.
In this case, it is recommended that a low Equivalent Series Resistance (ESR <1.0
at 100 kHz) capacitor
be mounted close to the converter.A 33 µF is recommended for 24V input models and a 10 µF for 48V units.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above
for the correct rating.
Heatsink Notes:
• Use of the heatsink will extend the units operating temperature
range by approximately 10°C.
• The heatsink is black anodized aluminum.
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
A simple external circuit may be used to adjust
the converter output. To adjust the output DOWN,
connect a 5%, 3W resistor between the plus output
pin and the Vout trim pin. To adjust the output UP,
connect a 5%, 3W resistor between the minus
output pin and the Vout trim pin. To calculate the
correct resistor value use:
UP
Radj =
(33 x Vout) - (30 x Vadj)
Vadj - Vout
Down
Radj =
(36.667 x Vout) - (33 x Vout)
Vout - Vadj
For UP/Down trimming capability, connect a 10
kW potentiometer between the plus and minus
outputs with the wiper arm connected to the
Vout trim pin.
Pin
Single
Dual
Pin
Single
Dual
1
+Vin
+Vin
6
+Vout
Comm.
2
-Vin
-Vin
7
-Vout
-Vout
4
ON/OFF ON/OFF
8
Trim
Trim
5
No Pin
+Vout
Pin Connections
Model
Number
Input
Output
Over
Voltage
Protection
(VDC)
Efficiency
(%, Typ)
Capacitive
Load
(µF Max)
Fuse Rating
Slow-Blow
(mA)
Voltage (VDC)
Current (mA)
Voltage
(VDC)
Current
(mA, Max)
Current
(mA, Min)
Nominal
Range
Full-Load No-Load
F2501RU
24
10.0 - 40.0
922
20
3.3
5,500
400.0
3.9
82
1,000
5,000
F2502RU
24
10.0 - 40.0
1,225
20
5.0
5,000
350.0
6.8
85
1,000
5,000
F2503RU
24
10.0 - 40.0
1,404
20
12.0
2,500
166.0
15.0
89
1,000
5,000
F2504RU
24
10.0 - 40.0
1,404
20
15.0
2,000
133.0
18.0
89
1,000
5,000
F2505RU
24
10.0 - 40.0
1,404
20
±12.0
±1,250
±83.0
±15.0
89
±330
5,000
F2506RU
24
10.0 - 40.0
1,404
20
±15.0
±1,000
±65.0
±18.0
89
±330
5,000
F2511RU
48
18.0 - 75.0
461
10
3.3
5,500
400.0
3.9
82
1,000
3,000
F2512RU
48
18.0 - 75.0
613
10
5.0
5,000
350.0
6.8
85
1,000
3,000
F2513RU
48
18.0 - 75.0
702
10
12.0
2,500
166.0
15.0
89
1,000
3,000
F2514RU
48
18.0 - 75.0
702
10
15.0
2,000
133.0
18.0
89
1,000
3,000
F2515RU
48
18.0 - 75.0
702
10
±12.0
±1,250
±83.0
±15.0
89
±330
3,000
F2516RU
48
18.0 - 75.0
702
10
±15.0
±1,000
±65.0
±18.0
89
±330
3,000
Mechanical Dimensions
External Trim
Derating Curves
Heatsink Dimensions (Optional)
For Heatsink Option, add suffix “H” to model number (i.e. F2503RU-H)
www.micropowerdirect.com



Html Pages

1 2


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com