| Electronic Components Datasheet Search |
|
PAXUSB00 Datasheet(PDF) 2 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
PAXUSB00 Datasheet(HTML) 2 Page - List of Unclassifed Manufacturers |
|
2 / 2 page ![]() * - Disregard these parameters when configuring unit to upload or download wth Crimson software. Red Lion Controls 20 Willow Springs Circle York PA 17406 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 Red Lion Controls AP Unit 101, XinAn Plaza Building 13, No.99 Tianzhou Road ShangHai, P.R. China 200223 Tel +86 21 6113-3688 Fax +86 21 6113-3683 Red Lion Controls BV Printerweg 10 NL - 3821 AD Amersfoort Tel +31 (0) 334 723 225 Fax +31 (0) 334 893 793 ! " !"## $%&' ! " ( '%)% DATA BIT * ! " *+, %$-. ! " /0 01) ABBREVIATED PRINTING * PRINT OPTIONS * ! " 0'' 1%- PARITY BIT * ! " # %''- METER ADDRESS 300 1200 600 2400 19200 4800 9600 7 8 Odd EVEN NO 0 to 99 YES NO YES NO It is necessary to match the PAX meter’s serial communications parameters to the host’s parameters before communications can be established. This is accomplished by using the PAX front panel keys to enter (2,-3. The only paramters of concern when utilizing the PAXUSB programming option card to communicate with Crimson 2 programming software is the Baud Rate and Meter Address. The Parameters are only accessible when an optional PAXUSB, RS232 or RS485 serial communications card is installed. MODULE 7 - SERIAL COMMUNICATIONS PARAMETERS (!"#$%) PARAMETER MENU BAUD RATE Indicates Program Mode Alternating Display. Factory Settings are shown. ! " !"## $%&' Parameter Selection/Value Set the baud rate to match that of other serial communications equipment. Normally, the baud rate is set to the highest value that all of the serial communications equipment is capable of transmitting. Select either 7 or 8 bit data word lengths. Set the word length to match that of other serial communication equipment. Since the meter receives and transmits 7-bit ASCII encoded data, 7 bit word length is sufficient to request and receive data from the meter. Set the parity bit to match that of the other serial communications equipment used. The meter ignores the parity when receiving data, and sets the parity bit for outgoing data. If no parity is selected with 7-bit word length the meter transmits and receives data with 2 stop bits. (For example: 10 bit frame with mark parity) Enter the serial node address. With a single unit on a bus, an address is not needed and a value of zero can be used (RS232 applications). Otherwise, with multiple bussed units, a unique address number must be assigned to each meter. The node address applies specifically to RS485 applications. Select abbreviated transmissions (numeric only) or full field transmission. When the data from the meter is sent directly to a terminal for display, the extra characters that are sent identify the nature of the meter parameter displayed. In this case, select /0. When the data from the meter goes to a computer, it may be desirable to suppress the node address and mnemonic when transmitting. In this case, set this parameter to 4+5. 4+5 - Enters the sub-menu to select those meter parameters to appear in the block print. For each parameter in the sub-menu select 4+5 for the parameter to appear with the block print, and /0 to disable the parameter. * - Disregard these parameters when configuring unit to upload or download wth Crimson. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |