| Electronic Components Datasheet Search |
|
LRD4367 Datasheet(PDF) 21 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
LRD4367 Datasheet(HTML) 21 Page - List of Unclassifed Manufacturers |
|
21 / 56 page ![]() www.schneider-electric.us © 2009 Schneider Electric All Rights Reserved 18-21 Enclosed Starters TeSys® D in Metal Enclosures Refer to Catalog 8502CT9901 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-48 TeSys D enclosed full voltage starters are available in Type 1 and Type 12/3R enclosures through 50 hp at 460 V. The enclosed D-line accepts standard D-Line accessories and all Insta-Kits™ control units and control power transformer kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure. For extra capacity, please refer to your local distributor or nearest Square D/Schneider Electric sales office. Table 18.69: Enclosed Full Voltage Non-reversing Starters Max. Horsepower Ratings (AC3) Auxiliary Contacts Current Rating of Contactor Catalog Number $ Price Catalog Number $ Price 1 Phase 3 Phase 115 230 200 V 230 V 460 V 575V N.O. N.C. Type 1 Type 12/3R 0.333 1 2 2 5 7.5 1 1 9 LE1D093A62••••• 109. LE1D093A72••••• 175. 0.5 2 3 3 7.5 10 1 1 12 LE1D123A62••••• 137. LE1D123A72••••• 202. 1 3 5 5 10 15 1 1 18 LE1D183A62••••• 153. LE1D183A72••••• 219. 2 3 5 7.5 15 20 1 1 25 LE1D253A62••••• 170. LE1D253A72••••• 235. 2 5 7.5 10 20 25 1 1 32 LE1D323A62••••• 191. LE1D323A72••••• 245. 3 5 10 10 30 30 1 1 40 LE1D403A62••••• 273. LE1D403A72••••• 393. 3 7.5 12 15 40 40 1 1 50 LE1D503A62••••• 300. LE1D503A72••••• 420. 5 10 20 20 40 50 1 1 65 LE1D653A62••••• 393. LE1D653A72••••• 514. 7.5 15 30 30 60 60 1 1 80 LE1D803A62••••• 473. LE1D803A72••••• 610. Table 18.70: Enclosed Full Voltage Reversing Starters Max. Horsepower Ratings (AC3) 3 Phase Auxiliary Contacts On Each Contactor Current Rating of Contactor Catalog Number $ Price Catalog Number $ Price 200V 230 V 460 V 575 V N.O. N.C. Type 1 Type 12/3R 2 2 5 7.5 1 1 9 LE2D093A62••••• 305. LE2D093A72••••• 382. 3 3 7.5 10 1 1 12 LE2D123A62••••• 355. LE2D123A72••••• 453. 5 5 10 15 1 1 18 LE2D183A62••••• 385. LE2D183A72••••• 483. 5 7.5 15 20 1 1 25 LE2D253A62••••• 415. LE2D253A72••••• 513. 7.5 10 20 25 1 1 32 LE2D323A62••••• 464. LE2D323A72••••• 573. 10 10 30 30 1 1 40 LE2D403A62••••• 655. LE2D403A72••••• 819. 12 15 40 40 1 1 50 LE2D503A62••••• 710. LE2D503A72••••• 874. 20 20 40 50 1 1 65 LE2D653A62••••• 900. LE2D653A72••••• 1030. 30 30 60 60 1 1 80 LE2D803A62••••• 1248. LE2D803A72••••• 1412. Table 18.71: Catalog Number Nomenclature f Control Power Transformer Add price from page 18-23. Select letter for primary voltage of CPT: Voltage No Transformer used 208 240 480 600 Code O a LM T X a Letter O, not zero. Note: If control transformer is used, the only options available are 24 or 120 volts as the secondary of the transformer. Also, DC voltages are not available when control power transformer is used. g Contactor/Starter Coil Voltage Select coil voltage from table: Voltage 24 120 208 240 480 600 AC BG L U T X DC B ————— h Coil Frequency Select: 7 = dual frequency coils (50/60 Hz.) 6 = 60 Hz. D=DC Note: For 9 to 65 A contactors, only dual frequency coils are available; 80 A contactors, the 24 V to 240 V coils are dual frequency only (50/60 Hz.). The 480 V to 600 V coils are 60 Hz. only. See catalog for other restrictions. j Overload relay type Select: 0 = No overload relay 1 = Class 10 Trip 2 = Class 20 Trip LE1D093A62 O G 7 1 07 Overload Relay Range i Overload Relay Type j Coil Frequency h Contactor/Starter Coil Voltage g Control Power Transformer f Wiring Method Base Catalog Number Catalog Number Example: i Overload Relay Range Select code from the below: Code Range For use on Contactors $ Price Adder 01 0.1–0.16 D09–D32b 60. 02 0.16–0.25 D09–D32b 60. 03 0.25–0.40 D09–D32b 60. 04 0.40–0.63 D09–D32b 60. 05 0.63–1.0 D09–D32b 60. 06 1.0–1.6 D09–D32b 60. 07 1.6–2.5 D09–D32b 60. 08 2.5–4 D09–D32 60. 10 4–6 D09–D32 60. 12 5.5–8 D09–D32 60. 13 9–13 D40, D50, D65 107. 14 7–10 D09–D32 62. 16 9–13 D12–D32 62. 18 12–18 D40, D50, D65 107. 21 12–18 D18–D32 62. 22 16–24 D25–D32b 62. 17–25 D25–D32c 62. 17–25 D80 107. 25 17–25 D40, D50, D65 107. 30 23-28 D25–D32c 73. 32 23–32 D25–D32 73. 32 23–32 D40, D50, D65 107. 40 30–40 D40, D50, D65 107. 50 37–50 D40, D50, D65 107. 53 30–38 D80 107. 55 30–40 D80 107. 57 37–50 D80 107. 59 48–65 D80 107. 61 55–70 D65–D80 107. 63 63–80 D65–D80 107. 65 48–65 D40, D50, D65 107. b Available for Class 10 only. c Available for Class 20 only. Note: If no overload relay is required, leave this portion of the catalog blank. Add appropriate Price Adder to the base price of the starter. I11 Discount Schedule |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |