17 / 19 page ![]() DocID026915 Rev 1 17/19 AN4586 Precision op amps 19 7 Precision op amps Table 5 lists some precision op amps that might be used for differential to single-ended measurements. 8 Conclusion In this application note, we looked at the three main architectures that allow us to perform differential measurements by rejecting the Vicm. Each has its own pros and cons such as a better CMRR, simpler architecture, high input impedance, or a smaller offset on the output voltage. This document highlights the importance of having very accurate resistors. For precise differential measurements, a 1 % resistor may be not enough. We also saw that a high precision op amp is useful for limiting the offset on the output voltage. Table 5. Some precision op amps Part number Vio max (µV) Vcc range (V) GBP (Hz) TSZ121 5 1.8 to 5.5 400 k TSV731 200 1.5 to 5.5 900 k TSX711 200 2.7 to 16 2.7 M TS512A 500 6 to 30 3 M |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|