13 / 25 page ![]() DocID10973 Rev 2 13/25 AN2067 Switching cycle 25 5 Switching cycle Figure 4 and Figure 5 show the drain voltage and drain current respectively in discontinuous mode and continuous mode, with a 40 W static load, and input voltage respectively at 400 V and 100 V. Figure 7 and Figure 9 present drain voltage, drain current, VCOMP and VOUT voltage in burst mode. The output (static) load is 4 W (40 V, 100 mA), and input voltage is respectively at 100 V and 400 V. Table 2. Transformer specifications Parameter Turn ratio Number of turns Number of wires Wire (mm) Max. current (A) Primary inductance Lprim: 0.5 mH Lleak < 4 µH (0.8%) core: E25H 52 2 0.4 2.3 Primary auxiliary winding 0.211 11 1 ~0.2 <0.1 Secondary winding 0.5 26 1 0.7 1 Secondary auxiliary winding 0.077 4 1 ~0.2 <0.1 Figure 4. Discontinuous mode (40 W/VIN=400 V) Figure 5. Burst mode (PLOAD=4 W; VIN=100 V) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|