| Electronic Components Datasheet Search |
|
UM0920 Datasheet(PDF) 11 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
UM0920 Datasheet(HTML) 11 Page - STMicroelectronics |
|
11 / 14 page ![]() UM0920 Measurements Doc ID 17220 Rev 2 11/14 4 Measurements The basic measurements for efficiency, load characteristics and conductive EMI are shown in Figure 5, Figure 6, Figure 7 and Figure 8. Figure 5. Efficiency at 120 VAC and 230 VAC Figure 6. Load characteristics of 12 V output at 120 VAC and 230 VAC 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 POUT (W) Standby at 120 VAC: 20 mW AM00898 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 POUT (W) Standby at 230 VAC: 35 mW 10 11 12 13 14 15 16 0 20 40 60 80 100 120 140 160 180 IOUT (mA) 5 V / 50 mA AM00899 10 11 12 13 14 15 16 0 20406080 100 120 140 160 180 IOUT (mA) 5 V / 50 mA 5 V / 100 mA 5 V / 200 mA 5 V / 400 mA 5 V / 100 mA 5 V / 200 mA 5 V / 400 mA 120 VAC 230 VAC |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|