13 / 27 page ![]() UM0116 Read/program the STR7 embedded Flash 13/27 Bit 15 PWD: Power Down Mode (Read/Write). When the microcontroller is put in a specific low power mode (see note below), the Flash module can be put into two different low power modes. 0: Normal Mode (default), Flash Stand-by mode is selected (immediate read from Flash is possible, but some residual power consumption is present). 1: The Flash module enters Power-Down mode. (recovery time of 20µs needed before reading, but lower power consumption) Note: In the STR71x family the PWD bit acts only in STOP and LPWFI modes. Whereas in the STR73x it acts only in LPWFI mode. For further details, refer to the specific STR7 microcontroller reference manual and datasheet, Power section. Bit 14:5 Reserved, must be kept at reset value (0). Bit 4 LOCK: Flash Register Access Locked (Read Only). When this bit is set, it means that the access to all the Flash control registers is locked: any read access to the registers will output invalid data (0xE6000010) and any write access will be ineffective. Please note that the “1” of the invalid data is located exactly in the position of the LOCK bit: therefore it is the only bit the user can always access to detect the status of the Flash registers. The LOCK bit is automatically set when the Flash bit WMS is set. Once it is found low, the rest of FLASH_CR0 and all the other Flash registers are user accessible. Bit 3 Reserved, must be kept at reset value (0). Bit 2:1 BSY[1:0]: Bank 1:0 Busy (Read Only). These bits indicate that a write operation is ongoing in the corresponding bank. They are automatically set when bit WMS is set. A Set Protection operation sets bit BSY0. When these bits are set any read access to the corresponding bank will output invalid data, while any write access to the bank will be ignored. At the end of the write operation or during a Program or Erase Suspend these bits are automatically reset and the bank returns to read mode. After a Program or Erase Resume these bits are automatically set again. All BSY[1:0] bits remain high for a maximum of 20 µs after Power-Up and when exiting Power- Down mode, meaning that the Flash banks are not yet ready to be accessed. Bit 0 Reserved, must be kept at reset value (0). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |